English
Language : 

X9241A_06 Datasheet, PDF (10/16 Pages) Intersil Corporation – Quad Digital Controlled Potentionmeters (XDCP™)
X9241A
Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . . . .-65 to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . .-65 to +150°C
Voltage on SCK, SCL or any address
input with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
Voltage on any VH/RH, VW/RW or VL/RL
referenced to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +6V/-4V
ΔV = |VH/RH - VL/RL| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10V
Lead temperature (soldering, 10s). . . . . . . . . . . . . . . . . . . . . +300°C
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Power rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mW
Recommended Operating Conditions
Temperature (Commercial) . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Temperature (Industrial). . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (VCC) Limits
X9241A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
Max Wiper Current for 2k RTOTAL . . . . . . . . . . . . . . . . . . . . . . ±4mA
Max Wiper Current for 10k and 50k RTOTAL . . . . . . . . . . . . . . ±3mA
CAUTION: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; the functional
operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Analog Specifications (Over recommended operating conditions unless otherwise stated.)
SYMBOL
PARAMETER
RTOTAL
RW
VTERM
End to end resistance
Wiper resistance
Voltage on any VH/RH, VW/RW or VL/RL Pin
Noise
Resolution
Absolute linearity (Note 1)
Relative linearity (Note 2)
Temperature coefficient of RTOTAL
Ratiometric temperature coefficient
CH/CL/CW
lAL
Potentiometer capacitances
RH, RI, RW leakage current
TEST CONDITION
MIN
-20
Wiper Current = ± 1mA
-3.0
Ref: 1kHz (Note 5)
(Note 5)
Rw(n)(actual) - Rw(n)(expected)
Rw(n + 1) - [Rw(n) + MI]
(Note 5)
(Note 5)
See Circuit #3 and (Note 5)
VIN = VTERM. Device is in stand-by
mode.
LIMITS
TYP
40
≤120
1.6
±300
±20
15/15/25
0.1
MAX
+20
130
+5
±1
±0.2
1
UNIT
%
Ω
V
dBV
%
MI(3)
MI(3)
ppm/°C
ppm/C
pF
µA
DC Electrical Specifications (Over recommended operating conditions unless otherwise stated.)
SYMBOL
PARAMETER
lCC
Supply current (active)
ISB
VCC current (standby)
ILI
Input leakage current
ILO
Output leakage current
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL Output LOW voltage
TEST CONDITION
fSCL = 100kHz, Write/Read to WCR,
Other Inputs = VSS
SCL = SDA = VCC, Addr. = VSS
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
LIMITS
MIN
TYP
200
2
MAX
3
500
10
10
0.8
0.4
UNIT
mA
µA
µA
µA
V
V
V
Notes: (1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as
a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potenti-
ometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (RH–RL)/63, single pot
(4) Max = all four arrays cascaded together, Typical = individual array resolutions.
10
FN8164.5
December 14, 2006