X9241A
Guidelines for Calculating
Typical Values of Bus Pull-Up Resistors
120
100
RMIN
=
VCC MAX
IOL MIN
=1.8kΩ
80
RMAX
= tR
CBUS
60
Max.
Resistance
40
20 Min.
Resistance
0
0 20 40 60
80 100 120
Bus Capacitance (pF)
DCP Wiper Current De-rating Curve
7
6
5
4
3
2
1
0
0 10 20 30 40 50 60 70 80 90
Ambient Temperature (°C)
tHIGH
tLOW
tF
tR
SCL
tSU:STA
tHD:STA tHD:DAT
tSU:DAT
tSU:STO
SDA
(Data in)
FIGURE 10. INPUT BUS TIMING
AC Electrical Specifications (Over recommended operating conditions unless otherwise stated.)
LIMITS
SYMBOL
PARAMETER
MIN
MAX
fSCL
tLOW
tHIGH
tR
tF
Ti(9)
tSU:STA
tHD:STA
tSU:DAT
tHD:DAT
tAA
tDH
tSU:STO
tBUF
tWR
tSTPWV
tCLWV
SCL clock frequency
Clock LOW period
Clock HIGH period
SCL and SDA rise time
SCL and SDA fall time
Noise suppression time constant (glitch filter)
Start condition setup time (for a repeated start condition)
Start condition hold time
Data in setup time
Data in hold time
SCL LOW to SDA data out valid
Data out hold time
Stop condition setup time
Bus free time prior to new transmission
Write cycle time (nonvolatile write operation)
Wiper response time from stop generation
Wiper response from SCL LOW
0
4700
4000
4000
4000
250
0
30
4000
4700
100
1000
300
20
3500
10
500
1000
tBUF
UNIT
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
µs
µs
REFERENCE
FIGURE
10
10
10
10
10
10
10 & 12
10 & 12
10
10
11
11
10 & 12
10
13
13
6
12
FN8164.5