X80120, X80121
Electrical Specifications (Programmable Parameters) Over the recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
tSPOR
Delay before RESET assertion
TPOR1 = 0 TPOR0 = 0
Factory Default
90
100
110
ms
TPOR1 = 0 TPOR0 = 1 (Note 3)
450
500
550
ms
TPOR1 = 1 TPOR0 = 0 (Note 3)
0.9
1
1.1
s
TPOR1 = 1 TPOR0 = 1 (Note 3)
4.5
5
5.5
s
tDELAYi
Time Delay used in Power Sequencing
(i = 1, 4)
TiD1 = 0 TiD0 = 0
Factory Default
90
100
110
ms
TiD1 = 0 TiD0 = 1
(Note 3)
450
500
550
ms
TiD1 = 1 TiD0 = 0
(Note 3)
0.9
1
1.1
s
TiD1 = 1 TiD0 = 1
(Note 3)
4.5
5
5.5
s
Equivalent A.C. Output Load Circuit
5V
5V
5V
SDA
4.6kâ¦
30pF
RESET
4.6kâ¦
30pF
V1GDO,
V4GDO
4.6kâ¦
30pF
A.C. Test Conditions
Input pulse levels
Input rise and fall times
Input and output timing levels
Output load
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Standard output load
VCC
Initial
Power-up
VTRIPi
ViMON
ViGDO
tDPOR
tDELAYi
tTO
FIGURE 1. INITIAL POWER UP TIMING
tDELAYi
i = 1, 4
4
FN8151.0