English
Language : 

HC5513_03 Datasheet, PDF (19/20 Pages) Intersil Corporation – TR909 DLC/FLC SLIC with Low Power Standby
HC5513
Application Circuit
RRT
CRT
R1
R3
RD
CHP (NOTE 32)
RFB
PTC
TIP
PTC
RING
RINGING
(VBAT + 90VRMS)
R4
R2
VBAT
RF1
D3
D1
NOTE 31
D4
D2
RF2 Surgector
K
A
G
D5
+5V
RELAY
OR
12V
1 HPT
U1
-5V
2 RD
3 DT
4 DR
5 TIPX
CTC
7 BGND
CRC
8 VCC
VBAT
RSG
-5V
6 RINGX
10 VBAT
9 RINGRLY
11 RSG
HPR 22
VTX 21
VEE 20
RSN 19
AGND 18
RDC 17
C1 16
C2 15
DET 14
EO 13
E1 12
RTX
-5V RT
RB
RRX
RDC1
RDC2
CDC
U2
+-
CODEC/FILTER
D6
U1 SLIC (Subscriber Line Interface Circuit)
HC5513
U2 Combination CODEC/Filter e.g.
CD22354A or Programmable CODEC/
Filter, e.g. SLAC
CDC 1.5µF, 20%, 10V
CHP 10nF, 20%, 100V (Note 2)
CRT 0.39µF, 20%, 100V
CTC, CRC 2200pF, 20%, 100V
Relay Relay, 2C Contacts, 5V or 12V Coil
D1 - D5 IN4007 Diode
Surgector SGT27S10
PTC Polyswitch TR600-150
D6 Diode, 1N4454
RF1, RF2 Line Resistor, 20Ω, 1% Match, 2 W
Carbon column resistor or thick film on
ceramic
R1, R3 200kΩ, 5%, 1/4W
R2 910kΩ, 5%, 1/4W
R4 1.2MΩ, 5%, 1/4W
RB 18.7kΩ,1%, 1/4W
RD 39kΩ, 5%, 1/4W
RDC1, RDC2 41.2kΩ, 5%, 1/4W
RFB 20.0kΩ, 1%, 1/4W
RRX 280kΩ, 1%, 1/4W
RT 562kΩ, 1%, 1/4W
RTX 20kΩ, 1%, 1/4W
RRT 150Ω, 5%, 2W
RSG VBAT = -28V, RSG = ∞
VBAT = -48V, RSG = 21.4kΩ, 1/4W 5%
NOTES:
31. It is recommended that the anodes of D3 and D4 be shorted to ground through a battery referenced surgector (SGT27S10).
32. To meet the specified 25dB 2-wire return loss at 200Hz, CHP needs to be 20nF, 20%, 100V.
FIGURE 21. APPLICATION CIRCUIT
19