The 4-wire transmit and receive signal paths should not
cross. The receive path is any trace associated with the VRX
input and the transmit path is any trace associated with VTX
output. The physical distance between the two signal paths
should be maximized to reduce crosstalk.
The mode control signals and detector outputs should be
routed away from the analog circuitry. Though the digital
signals are nearly static, care should be taken to minimize
coupling of the sharp digital edges to the analog signals.
The part has two ground pins, one is labeled AGND and the
other BGND. Both pins should be connected together as
close as possible to the SLIC. If a ground plane is available,
then both AGND and BGND should be connected directly to
the ground plane.
A ground plane that provides a low impedance return path
for the supply currents should be used. A ground plane
provides isolation between analog and digital signals. If the
layout density does not accommodate a ground plane, a
single point grounding scheme should be used.
VRX
VOUT1
HC55171
RA
RF
RB
CODEC
RX OUT
-
+
TX IN
+2.5V
+
-
FIGURE 20. SINGLE SUPPLY CODEC INTERFACE
Trapezoidal Ringing Application Circuit
U1
TIP
RING
VCC
VBAT
F1
F0
TST
RS1
RS2
CPS1
CPS2
VCC
HC55171
14 TIP SENSE
25 TF
VRX 17
ILIMT 11
RIL2
26 RF
RIL1
16 RING SENSE 2 VTX 19
CAC
15 RING SENSE 1
RRF
-IN1 13
2 VCC
1 AGND
OUT1 12
RTI 28
RZO
RRT2
22 BGND
RRT3
CRX
RRT1
CRT
DRT
27 VBAT
4 F1
5 F0
6 RS
9 TST
20 RDI
VRING 24
VREF 3
CIL
DTRAP
SHD 7
RTD 8
ALM 10
RTRAP
CTRAP
V-REC
V-XMIT
VRING
SHD
RTD
ALM
FIGURE 21. TRAPEZOIDAL RINGING APPLICATION CIRCUIT
18