English
Language : 

X40010 Datasheet, PDF (17/24 Pages) Xicor Inc. – Dual Voltage Monitor with Integrated CPU Supervisor
A.C. CHARACTERISTICS
X40010, X40011, X40014, X40015
Symbol
fSCL
tIN
tAA
tBUF
tLOW
tHIGH
tSU:STA
tHD:STA
tSU:DAT
tHD:DAT
tSU:STO
tDH
tR
tF
Cb
Parameter
SCL Clock Frequency
Pulse width Suppression Time at inputs
SCL LOW to SDA Data Out Valid
Time the bus free before start of new transmission
Clock LOW Time
Clock HIGH Time
Start Condition Setup Time
Start Condition Hold Time
Data In Setup Time
Data In Hold Time
Stop Condition Setup Time
Data Output Hold Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Capacitive load for each bus line
Note: (1) Cb = total capacitance of one bus line in pF.
400kHz
Min.
Max.
0
400
50
0.1
0.9
1.3
1.3
0.6
0.6
0.6
100
0
0.6
50
20 +.1Cb(1)
300
20 +.1Cb(1)
300
400
Unit
kHz
ns
µs
µs
µs
µs
µs
µs
ns
µs
µs
ns
ns
ns
pF
TIMING DIAGRAMS
Bus Timing
tF
tHIGH
SCL
tSU:STA
SDA IN
tHD:STA
tSU:DAT
tLOW
tHD:DAT
SDA OUT
tR
tAA tDH
tSU:STO
tBUF
17
FN8111.0
March 28, 2005