English
Language : 

X40010 Datasheet, PDF (14/24 Pages) Xicor Inc. – Dual Voltage Monitor with Integrated CPU Supervisor
X40010, X40011, X40014, X40015
ABSOLUTE MAXIMUM RATINGS
Temperature under bias .................... -65°C to +135°C
Storage temperature ......................... -65°C to +150°C
Voltage on any pin with
respect to VSS ...................................... -1.0V to +7V
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10 seconds) ........ 300°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
70°C
+85°C
Table 2:
Chip Supply Volt-
Version
age
X40010/11
-A or -B
2.7V to 5.5V
X40010/11-C
2 7V to 5 5V
Monitored*
Voltages
2.6V to 5V
1V to 3 6V
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified)
Symbol
ICC1(1)
ICC2(1)
Parameter
Active Supply Current (VCC) Read
Active Supply Current (VCC) Read
ISB1(1)(6) Standby Current (VCC) AC (WDT off)
ISB2(2)(6) Standby Current (VCC) DC (WDT on)
ILI
ILO
VIL(3)
VIH(3)
VHYS(6)
VOL
VOH
Input Leakage Current (SCL)
Output Leakage Current (SDA,
V2FAIL, WDO, RESET)
Input LOW Voltage (SDA, SCL)
Input HIGH Voltage (SDA, SCL)
Schmitt Trigger Input Hysteresis
• Fixed input level
• VCC related level
Output LOW Voltage (SDA, RE-
SET/RESET, V2FAIL, WDO)
Output (RESET) HIGH Voltage
VCC Supply
VTRIP1(5) VCC Trip Point Voltage Range
tRPD2(6) VTRIP2 to V2FAIL
Min.
-0.5
VCC x 0.7
Typ.(4)
6
25
Max.
1.5
3.0
10
30
10
10
VCC x 0.3
VCC + 0.5
Unit
Test Conditions
mA VIL = VCC x 0.1
mA VIH = VCC x 0.9,
fSCL = 400kHz
µA VIL = VCC x 0.1
VIH = VCC x 0.9
fSCL, fSDA = 400kHz
µA VSDA = VSCL = VCC
Others = GND or VCC
µA VIL = GND to VCC
µA VSDA = GND to VCC
Device is in Standby(2)
V
V
0.2
.05 x VCC
VCC - 0.8
VCC - 0.4
V
V
0.4
V IOL = 3.0mA (2.7-5.5V)
IOL = 1.8mA (2.7-3.6V)
V IOH = -1.0mA (2.7-5.5V)
IOH = -0.4mA (2.7-3.6V)
2.0
4.75
V
4.55
4.6
4.65
V X40010/11-A
4.35
4.4
4.45
V X40010/11-B
2.85
2.9
2.95
V X40010/11-C,
X40014/15-A&C
2.55
2.6
2.65
V X40014/15-B
5
µS
14
FN8111.0