ABSOLUTE MAXIMUM RATINGS
Parameter
Temperature under Bias
Storage Temperature
Voltage on WP pin (With respect to Vss)
Voltage on other pins (With respect to Vss)
| Voltage on RHx - Voltage on RLx | (x = 1,2. Referenced to Vss)
D.C. Output Current (SDA)
Lead Temperature (Soldering, 10 seconds)
Supply Voltage Limits (Applied Vcc voltage, referenced to Vss)
Min.
Max.
Units
-65
+135
°C
-65
+150
°C
-1.0
+15
V
-1.0
+7
V
Vcc
V
0
5
mA
300
°C
2.7
5.5
V
RECOMMENDED OPERATING CONDITIONS
Industrial
Temperature
Min.
Max.
Units
-40
+85
°C
NOTE: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only and the functional operation of the device at these or any other conditions above those listed in the
operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended peri-
ods may affect device reliability
Figure 20. Equivalent A.C. Circuit
SDA
Vcc = 5V
2300Ω
100pF
Figure 21. DCP SPICE Macromodel
RTOTAL
RHx
RLx
CL
CH
RW
10pF
10pF
CW
25pF
RWx
(x = 1,2)
15
FN8207.1
August 25, 2005