Absolute Maximum Ratings
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on SCK, CS, SI, SO, WP, HOLD, VCC
with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
ΔV = | (VH - VL) | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5V
Lead Temperature (soldering, 10s) . . . . . . . . . . . . . . . . . . . . +300°C
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Wiper Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3mA
Power Rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mW
Operating Conditions
Commercial Temperature Range. . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial Temperature Range . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (VCC) Limits (Note 4)
X9251. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
X9251-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Analog Characteristics (Over the recommended operating conditions unless otherwise specified.)
SYMBOL
RTOTAL
RTOTAL
RW
PARAMETER
End to End Resistance
End to End Resistance
End to End Resistance Tolerance
Wiper Resistance
VTERM
Voltage on any RH or RL Pin
Noise (Note 6)
Resolution
Absolute Linearity (Note 1)
TEST CONDITIONS
MIN
T version
U version
IW =
V(VCC)
RTOTAL
@ VCC = 3V
IW =
V(VCC)
RTOTAL
@ VCC = 5V
VSS = 0V
VSS
Ref: 1V
Rw(n)(actual) - Rw(n)(expected) (Note 5) -1
LIMITS
TYP
MAX
100
50
±20
300
UNITS
kΩ
kΩ
%
Ω
220
Ω
-120
0.4
VCC
V
dBV/√Hz
%
+1 MI (Note 3)
Relative Linearity (Note 2)
Rw(n + 1) - [Rw(n) + MI] (Note 5)
-0.6
+0.6 MI (Note 3)
Temperature Coefficient of RTOTAL
Ratiometric Temp. Coefficient
(Note 6)
(Note 6)
±300
±20
ppm/°C
ppm/°C
CH/CL/CW Potentiometer Capacitances
NOTES:
See Macro model, (Note 6)
10/10/25
pF
1. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
2. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
3. MI = RTOT/255 or (RH - RL)/255, single pot
4. During power up VCC > VH, VL, and VW.
5. n = 0, 1, 2, …,255; m = 0, 1, 2, …, 254.