English
Language : 

HMU16JC-35 Datasheet, PDF (10/13 Pages) Intersil Corporation – 16 x 16-Bit CMOS Parallel Multipliers
HMU16, HMU17
AC Electrical Specifications VCC = 5.0V ±5%, TA = 0oC to 70oC, Note 6
PARAMETER
SYMBOL
TEST
CONDITIONS
HMU16/HMU17-35
MIN
MAX
HMU16/HMU17-45
MIN
MAX
UNITS
Unclocked Multiply Time
Clocked Multiply Time
X, Y, RND Setup Time
X, Y, RND Hold Time
Clock Pulse Width High
Clock Pulse Width Low
MSPSEL to Product Out
Output Clock to P
Output Clock to Y
Three-State Enable Time
Three-State Disable Time
Clock Enable Setup Time
(HMU17 Only)
tMUC
tMC
tS
tH
tPWH
tPWL
tPDSEL
tPDP
tPDY
tENA
tDIS
tSE
Note 4
-
55
-
70
ns
-
35
-
45
ns
15
-
18
-
ns
2
-
2
-
ns
10
-
15
-
ns
10
-
15
-
ns
-
22
-
25
ns
-
22
-
25
ns
-
22
-
25
ns
-
22
-
25
ns
-
22
-
25
ns
15
-
15
-
ns
Clock Enable Hold Time
tHE
(HMU17 Only)
2
-
2
-
ns
Clock Low Hold Time CLKXY
Relative to CLKML
(HMU16 Only)
tHCL
Note 5
0
-
0
-
ns
Output Rise Time
tr
From 0.8V to 2.0V
-
8
-
8
ns
Output Fall Time
tf
From 2.0V to 0.8V
-
8
-
8
ns
NOTES:
4. Transition is measured at ±200mV from steady state voltage with loading specified in AC Test Circuit, V1 = 1.5V, R1 = 500Ω
and C1 = 40pF.
5. To ensure the correct product is entered in the output registers, new data may not be entered into the input registers before the output registers
have been clocked.
6. Refer to AC Test Circuit, with V1 = 2.4V, R1 = 500Ω and C1 = 40pF.
AC Test Circuit
AC Testing Input, Output Waveforms
DUT
V1
R1
C1 (SEE NOTE)
0.3V
0V
1.5V
1.5V
VOH
VOL
NOTE: Includes Stray and Jig Capacitance.
NOTE: AC Testing: All parameters tested as per test circuit. Input
rise and fall times are driven at 1ns/V.
10