English
Language : 

SMFLHP283R3S_16 Datasheet, PDF (9/15 Pages) Interpoint Corporation Company – SMFLHP Single and Dual DC-DC Converters
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC-DC Converters
28 Volt input – 100 Watt
Table 8: Electrical Characteristics -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
DUAL output models
PARAMETER
CONDITIONS
OUTPUT VOLTAGE
OUTPUT CURRENT 2
+ VOUT
- VOUT
Either OUTPUT
VIN = 19 to 40 V
OUTPUT POWER 2
TOTAL
Either OUTPUT
VIN = 19 to 40 V
OUTPUT RIPPLE
10 kHz - 2 MHz, ±VOUT
LINE REGULATION
VIN = 19 TO 40 V
LOAD REGULATION
NO LOAD TO FULL
CROSS REGULATION
TOTAL
TC = 25°C
TC = -55°C TO +125°C
+ VOUT
- VOUT
+ VOUT
- VOUT
SEE NOTE 3
TC = 25°C
INPUT VOLTAGE
NO LOAD TO FULL
SEE NOTE 4
CONTINUOUS
TRANSIENT 50 ms 1, 5
INPUT CURRENT
NO LOAD
INHIBITED - INH1
INHIBITED - INH2
INPUT RIPPLE CURRENT 10 kHz - 10 MHz
EFFICIENCY
BALANCED LOAD
LOAD FAULT
SHORT CIRCUIT
STEP LOAD RESPONSE 6
± VOUT, 50% - 100% - 50%
STEP LINE RESPONSE 1, 6
TC = 25°C
TC = -55°C TO +125°C
POWER DISSIPATION
RECOVERY 1
TRANSIENT
RECOVERY 1
TRANSIENT
± VOUT, 19 - 40 - 19 V
START-UP 7
Capacitive Load 1, 8, 9
RECOVERY
DELAY
OVERSHOOT 1
TC = 25°C
SMFLHP2805D
MIN TYP MAX
4.85 5.00 5.15
4.82 5.00 5.18
0
±8
11.2
—
—
16.0
0
±40
56
0
—
80
—
25
100
—
—
150
—
0
50
—
25
100
—
0
50
—
25
100
—
—
400
—
—
400
19
28
40
0
—
80
—
50
80
—
9
14
—
35
80
—
30
80
75
80
—
73
—
—
—
15
25
—
1.5
10
— ±350 ±450
—
1.5
3.0
— ±250 ±600
—
200 300
—
3.5
20
—
0
25
—
—
500
SMFLHP2812D
MIN TYP MAX
11.64 12.00 12.36
11.58 12.00 12.42
0
±3.75 5.3
0
—
7.5
0
±45
63
0
—
90
—
50
125
—
—
175
—
0
50
—
25
100
—
10
100
—
50
200
—
—
480
—
—
480
19
28
40
0
—
80
—
50
120
—
9
14
—
35
80
—
30
80
83
86
—
81
—
—
—
15
22
—
1.5
4.0
— ±450 ±700
—
1.5
3.0
— ±250 ±800
—
200 600
—
3.5
20
—
0
50
—
—
500
SMFLHP2815D
MIN TYP MAX
14.55 15.00 15.45
14.47 15.00 15.53
0
±3.33 4.67
0
—
6.67
0
±50
70
0
—
100
—
50
120
—
—
225
—
0
50
—
25
100
—
10
100
—
50
200
—
—
600
—
—
600
19
28
40
0
—
80
—
50
120
—
9
14
—
35
80
—
30
80
82
87
—
80
—
—
—
15
21
—
1.5
4.0
— ±450 ±700
—
1.5
3.0
— ±250 ±800
—
200 600
—
3.5
20
—
0
50
—
—
500
UNITS
V
A
W
mV p-p
mV
mV
mV
V
V
mA
mA p-p
%
W
ms
mV pk
ms
mV pk
µs
ms
mV pk
µF
Notes
1. Guaranteed by characterization test and/or analysis. Not a production test.
2. Up to 70% of the total output power/current is available from either output
provided the opposite output is carrying 30% of the power/current in use.
3. Effect on negative Vout from 50%/50% loads to 30%/70% or 70%/30% loads.
4. Effect on negative Vout from 50%/50% loads to 10% then 50% load on
negative Vout
5. Converter will shut down above approximately 45 volts but will be undamaged
and will restart when voltage drops into normal range.
6. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
7. Tested on release from inhibit.
8. No affect on dc  performance.
9. Applies to each output.
www.craneae.com/interpoint
Page 9 of 15
Rev AC - 2016.02.17