SMFLHP283R3S_16 Datasheet, PDF (1/15 Pages) Interpoint Corporation Company – SMFLHP Single and Dual DC-DC Converters | |||
|
Crane Aerospace & Electronics Power Solutions
SMFLHP Single and Dual DC-DC Converters
28 Volt input â 100 Watt
Features
⢠Radiation tolerant space dc-dc converter
-- Single event effects (SEE) LET performance to
86 MeV cm2/mg
-- Total ionizing dose (TID) guaranteed per MIL-STD-883 method
1019, radiation hardness assurance (RHA)
P = 30 krad(Si), L = 50 krad(Si), R = 100 krad(Si)
-- 50 - 300 rad(Si)/sec dose rate (Condition A)
-- 10 mrad(Si)/sec dose rate (Condition D)
⢠Parallel up to 3 convertersâmaximum recommended power
is 80% of the total available power.
⢠Operating temperature -55°C to +125°C
⢠Qualified to MIL-PRF-38534 Class H and K
⢠Input voltage range 19 to 40 volts
⢠Transient protection up to 80 volts for 50 ms
-- Converter will shut down at an input voltage
above approximately 45 volts
⢠Fully isolated, magnetic feedback
⢠Fixed high switching frequency
⢠Remote sense and output trim on single output models
⢠Primary and secondary inhibit function
⢠Synchronization input and output
⢠Indefinite short circuit protection
⢠High power density with up to 87% typical efficiency
MODELS
Output Voltage (V)
SINGLE DUAL
3.3
±5
5
±12
12
±15
15
description
The Interpoint® SMFLHP Series⢠28 volt dc-dc converters are
rated up to 100 watts output power over a -55°C to +125°C
Âtemperature range with a 28 volt nominal input. On dual output
models, up to 70% of the rated output power can be drawn from
either the positive or negative outputs. The welded, hermetically
sealed package is only 3.005 x 1.505 x 0.400 inches.
ââ
Screening
SMFLHP converters offer screening options to space prototype
(O), Class H or K and radiation hardness assurance (RHA) levels
P - 30 krad(Si), L - 50 krad(Si) or R - 100 krad(Si). Single event
effects (SEE) LET performance to 86 MeV cm2/mg. See Tableâ9
on page 14 and Tableâ10 on page 15 for more information.
Design Features
The SMFLHP Series converters are switching regulators that use
a quasi-square wave, single ended forward converter design with
a constant switching frequency of 600 kHz.
Isolation between input and output circuits is provided with a
transformer in the forward path and wide bandwidth magnetic
coupling in the feedback control loop. The SMFLHP Series
uses a unique dual loop feedback technique that controls output
current with an inner feedback loop and output voltage with a
cascaded voltage mode feedback loop.
The additional secondary current mode feedback loop improves
transient response in a manner similar to primary current mode
control and allows for ease of paralleling.
Tight load regulation is achieved through a wide-bandwidth
magnetic feedback circuit.
Inhibit
The SMFLHP Series converters have two inhibit terminals (Inhibit
1 and Inhibit 2) that can be used to disable power conversion,
resulting in a very low quiescent input current. See Tableâ5 on
page 6 for specifications.
Sync
Converters may be synced to an external clock (525 to 675 kHz)
or to one another by using the sync in or out pins. See Tableâ5 on
page 6 for specifications.
Crane Aerospace & Electronics
Power Solutions â Interpoint Products
10301 Willows Rd. NE, Redmond, WA 98052
+1 425-882-3100 ⢠power@crane-eg.com
www.craneae.com/interpoint
Page 1 of 15
Rev AC - 2016.02.17
|
▷ |