28 Volt input – 100 Watt
Table 5: Operating Conditions, All Models, 25°C case, 28 Vin, 100% load, unless otherwise specified.
PARAMETER
LEAD SOLDERING TEMPERATURE 1
STORAGE TEMPERATURE 1
CASE OPERATING
TEMPERATURE
DERATING OUTPUT POWER/CURRENT 1
ESD Rating 1
MIL-PRF-38534, 3.9.5.8.2
ISOLATION: input to output or
ANY pin to case
INPUT TO OUTPUT CAPACITANCE 1
current limit 2
UNDERVOLTAGE LOCKOUT 1
-55°C TO +125°C
AUDIO REJECTION 1
CONVERSION FREQUENCY, Free Run
-55°C TO +125°C
SYNCHRONIZATION IN
-55°C TO +125°C
SYNCHRONIZATION OUT
INHIBIT 1 ACTIVE LOW (OUTPUT DISABLED)
Do not apply a voltage to the inhibit pin. 3
INHIBIT 1 ACTIVE HIGH (OUTPUT ENABLED)
Do not apply a voltage to the inhibit pin. 3
INHIBIT 2 ACTIVE LOW (OUTPUT DISABLED)
Do not apply a voltage to the inhibit pin. 3
INHIBIT 2 ACTIVE HIGH (OUTPUT ENABLED)
Do not apply a voltage to the inhibit pin. 3
CONDITIONS
10 seconds max.
FULL POWER
ABSOLUTE 1
LINEARLY
MIL STD 883 Method 3015
Class 3B
@ 500 VDC at 25°C
% of Full Load
Rising VIN (Turn On)
Falling VIN (Turn off)
15 Dual
All other Models
INPUT FREQUENCY
DUTY CYCLE 1
ACTIVE LOW
ACTIVE HIGH 1
REFERENCED TO
IF NOT USED
REFERENCED TO
IF NOT USED
inhibit pin pulled low
INHIBIT PIN SOURCE CURRENT 1
REFERENCED TO
INHIBIT PIN CONDITION
OPEN INHIBIT PIN VOLTAGE 1
inhibit pin pulled low
INHIBIT PIN SOURCE CURRENT 1
REFERENCED TO
INHIBIT PIN CONDITION
OPEN INHIBIT PIN VOLTAGE 1
All Models
MIN TYP MAX
UNITS
—
—
300
°C
-65
—
+150
°C
-55
—
+125
°C
-55
—
+135
From 100% at 125°C to 0% at 135°C
>8000
V
100
—
—
Megohms
—
150
—
pF
—
125
—
%
16.0
—
18.5
V
13.4
—
16.7
—
50
—
dB
525
—
675
kHz
550
—
650
525
—
675
kHz
40
—
60
%
—
—
0.8
V
4.5
—
5.0
INPUT COMMON
CONNECT TO INPUT COMMON
INPUT COMMON
Leave unconnected
—
—
0.8
V
—
—
10
mA
INPUT COMMON
OPEN COLLECTOR OR UNCONNECTED
9
—
12
V
—
—
0.5
V
—
—
5
mA
OUTPUT COMMON
OPEN COLLECTOR OR UNCONNECTED
—
—
9
V
For mean time between failures (MTBF) contact Applications Engineering
Notes
powerapps@crane-eg.com +1 425-882-3100 option 7
1. Guaranteed by characterization test and/or analysis. Not a production test.
3. An external inhibit interface should be used to pull the inhibits low or leave them
2. Dual outputs: The over-current limit will trigger when the sum of the currents from
floating. The inhibit pins can be left unconnected if not used.
both outputs reaches 125% (typical value) of the maximum rated “total” current of
both outputs.
www.craneae.com/interpoint
Page 6 of 15
Rev AC - 2016.02.17