TLF4949 Datasheet, PDF (9/23 Pages) Infineon Technologies AG – 5V Low Drop Out Linear Voltage Regulator
TLF4949
4.4
Electrical Characteristics
4.4.1 Voltage Regulator
Electrical Characteristics: Regulator
VIN = 14 V, Tj = -40°C to +125°C, all voltages with respect to ground, direction of current as shown in Figure 4
“Application Diagram” on Page 15 (unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
4.4.1
4.4.2
Output Voltage
4.4.3
4.4.4
4.4.5
Dropout Voltage
VDR = VIN - VOUT
4.4.6
4.4.7
Input to Output Voltage
Difference in Undervoltage
Condition
Current Sink Capability from
Output to GND
VOUT
VDR
VIO
Iouth2)
4.95 5
4.90 5
5.05 V
5.10 V
4.85 –
5.15 V
4.85 5
5.15
0.1 0.25 V
0.2 0.4 V
0.3 0.5 V
–
0.17 0.4 V
TJ = 25°C; IOUT = 1mA
6V ≤ VIN ≤ 28V;
1mA ≤ IOUT ≤ 50mA
VIN = 40V1);
5mA ≤ IOUT ≤ 100mA
6V ≤ VIN ≤ 28V;
0mA ≤ IOUT ≤ 100mA
IOUT = 10mA
IOUT = 50mA
IOUT = 100mA
VIN = 3.5V;
IOUT = 35mA
-30 -55 –
µA VIN = 25V; VOUT = 5.5V
4.4.8 Line Regulation
4.4.9 Load Regulation
ΔVOUT,line –
1
15
mV 6V < VIN < 28V;
IOUT = 1mA
ΔVOUT,load –
4
20
mV 1mA ≤ IOUT ≤ 100mA
4.4.10 Current Limit
IOUT,lim
120 240 400 mA VOUT = 4.5V
180
mA VOUT = 0V 3)
4.4.11 Quiescent Current
IQSE
–
180 300 µA IOUT = 0.3mA
4.4.12 Quiescent Current
IQ
–
–
3.6
mA IOUT = 100mA
1) VIN = 40V may be only applied as transient supply voltage to the device for maximum period of tTR < 1s. Please note that
also for such transient conditions, especially under higher load conditions, the absolute maximum rating of TJ must be
respected at any time. If transient conditions up to VIN = 40V and elevated load currents are expected in the application a
sufficient cooling must be provided to meet the power dissipation. Testing this parameter for the maximum allowed period
of T = 1s is for thermal reasons not subject to production test but guaranteed by design.
2) The test of this parameter ensures that the output voltage will not exceed 5.5V in a corresponding “no load current”-
condition. A sufficiently high value for Iouth will allow the output to react in a fast manner in case of a sudden decrease of
load current (e.g. if load is switching to standby or powerdown mode) .
3) Foldback characteristic.
Data Sheet
9
Rev. 1.0, 2012-05-07