English
Language : 

TLE94112EL Datasheet, PDF (72/80 Pages) Infineon Technologies AG – a protected twelve-fold half-bridge driver designed especially for automotive motion control applications
TLE94112EL
Serial Peripheral Interface (SPI)
SYS_DIAG_7 : OP_ERROR_6_STAT
Open load error status of half-bridge outputs 9 - 12 (Address Byte [OP]010 01[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
HB12_HS_OL HB12_LS_OL HB11_HS_OL HB11_LS_OL HB10_HS_OL HB10_LS_OL HB9_HS_OL HB9_LS_OL
r
rc
rc
rc
rc
rc
rc
rc
rc
Field
Bits
HB12_HS_OL D7
HB12_LS_OL D6
HB11_HS_OL D5
HB11_LS_OL D4
HB10_HS_OL D3
HB10_LS_OL D2
HB9_HS_OL D1
HB9_LS_OL D0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
High-side (HS) switch of half-bridge 12 open load detection
0B No error on HS12 switch (default value)
1B Open load detected on HS12 switch. Error latched.
Low-side (LS) switch of half-bridge 12 open load detection
0B No error on LS12 switch (default value)
1B Open load detected on LS12 switch. Error latched.
High-side (HS) switch of half-bridge 11 open load detection
0B No error on HS11 switch (default value)
1B Open load detected on HS11 switch. Error latched.
Low-side (LS) switch of half-bridge 11 open load detection
0B No error on LS11 switch (default value)
1B Open load detected on LS11 switch. Error latched.
High-side (HS) switch of half-bridge 10 open load detection
0B No error on HS10 switch (default value)
1B Open load detected on HS10 switch. Error latched.
Low-side (LS) switch of half-bridge 10 open load detection
0B No error on LS10 switch (default value)
1B Open load detected on LS10 switch. Error latched.
High-side (HS) switch of half-bridge 9 open load detection
0B No error on HS9 switch (default value)
1B Open load detected on HS9 switch. Error latched.
Low-side (LS) switch of half-bridge 9 open load detection
0B No error on LS9 switch (default value)
1B Open load detected on LS9 switch. Error latched.
Data Sheet
72
1.0
2016-08-27