SYS_DIAG_6 : OP_ERROR_5_STAT
Open load error status of half-bridge outputs 5 - 8 (Address Byte [OP]100 01[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
HB8_HS_OL HB8_LS_OL HB7_HS_OL HB7_LS_OL HB6_HS_OL HB6_LS_OL HB5_HS_OL HB5_LS_OL
r
rc
rc
rc
rc
rc
rc
rc
rc
Field
Bits
HB8_HS_OL D7
HB8_LS_OL D6
HB7_HS_OL D5
HB7_LS_OL D4
HB6_HS_OL D3
HB6_LS_OL D2
HB5_HS_OL D1
HB5_LS_OL D0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
High-side (HS) switch of half-bridge 8 open load detection
0B No error on HS8 switch (default value)
1B Open load detected on HS8 switch. Error latched.
Low-side (LS) switch of half-bridge 8 open load detection
0B No error on LS8 switch (default value)
1B Open load detected on LS8 switch. Error latched.
High-side (HS) switch of half-bridge 7 open load detection
0B No error on HS7 switch (default value)
1B Open load detected on HS7 switch. Error latched.
Low-side (LS) switch of half-bridge 7 open load detection
0B No error on LS7 switch (default value)
1B Open load detected on LS7 switch. Error latched.
High-side (HS) switch of half-bridge 6 open load detection
0B No error on HS6 switch (default value)
1B Open load detected on HS6 switch. Error latched.
Low-side (LS) switch of half-bridge 6 open load detection
0B No error on LS6 switch (default value)
1B Open load detected on LS6 switch. Error latched.
High-side (HS) switch of half-bridge 5 open load detection
0B No error on HS5 switch (default value)
1B Open load detected on HS5 switch. Error latched.
Low-side (LS) switch of half-bridge 5 open load detection
0B No error on LS5 switch (default value)
1B Open load detected on LS5 switch. Error latched.