English
Language : 

TLE94112EL Datasheet, PDF (69/80 Pages) Infineon Technologies AG – a protected twelve-fold half-bridge driver designed especially for automotive motion control applications
TLE94112EL
Serial Peripheral Interface (SPI)
SYS_DIAG_4 : OP_ERROR_3_STAT
Overcurrent error status of half-bridge outputs 9 - 12(Address Byte [OP]111 10[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
HB12_HS_OC HB12_LS_OC HB11_HS_OC HB11_LS_OC HB10_HS_OC HB10_LS_OC HB9_HS_OC HB9_LS_OC
r
rc
rc
rc
rc
rc
rc
rc
rc
Field
Bits
HB12_HS_OC D7
HB12_LS_OC D6
HB11_HS_OC D5
HB11_LS_OC D4
HB10_HS_OC D3
HB10_LS_OC D2
HB9_HS_OC D1
HB9_LS_OC D0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
High-side (HS) switch of half-bridge 12 overcurrent detection
0B No error on HS12 switch (default value)
1B Overcurrent detected on HS12 switch. Error latched and
HS12 disabled.
Low-side (LS) switch of half-bridge 12 overcurrent detection
0B No error on LS12 switch (default value)
1B Overcurrent detected on LS12 switch. Error latched and
LS12 disabled.
High-side (HS) switch of half-bridge 11 overcurrent detection
0B No error on HS11 switch (default value)
1B Overcurrent detected on HS11 switch. Error latched and
HS11 disabled.
Low-side (LS) switch of half-bridge 11 overcurrent detection
0B No error on LS11 switch (default value)
1B Overcurrent detected on LS11 switch. Error latched and
LS11 disabled.
High-side (HS) switch of half-bridge 10 overcurrent detection
0B No error on HS10 switch (default value)
1B Overcurrent detected on HS10 switch. Error latched and
HS10 disabled.
Low-side (LS) switch of half-bridge 10 overcurrent detection
0B No error on LS10 switch (default value)
1B Overcurrent detected on LS10 switch. Error latched and
LS10 disabled.
High-side (HS) switch of half-bridge 9 overcurrent detection
0B No error on HS9 switch (default value)
1B Overcurrent detected on HS9 switch. Error latched and HS9
disabled.
Low-side (LS) switch of half-bridge 9 overcurrent detection
0B No error on LS9 switch (default value)
1B Overcurrent detected on LS9 switch. Error latched and LS9
disabled.
Note:
Unused or not connected outputs for lower derivatives, i.e. TLE94110EL, TLE94108EL and
TLE94106EL will be defined as ‘reserved’, always reads as ‘0’
Data Sheet
69
1.0