English
Language : 

TLE6240GP Datasheet, PDF (6/23 Pages) Infineon Technologies AG – Smart 16-fold Low-Side Switch
Data Sheet TLE 6240 GP
Electrical Characteristics cont.
Parameter and Conditions
VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
Symbol Values
min typ
Unit
max
5. Diagnostic Functions
Open Load Detection Voltage
Output Pull Down Current
Fault Delay Time
Short to Ground Detection Voltage
Short to Ground Detection Current
Overload Detection Threshold
Overtemperature Shutdown Threshold5
Hysteresis5
VDS(OL)
VS -2.5 VS -2 VS -1.3
V
VReset = H
IPD(OL)
50 90
150
µA
td(fault)
50 100 200
µs
VDS(SHG) VS –3.3 VS -2.9 VS -2.5
V
VReset = H ISHG
-50 -100 -150 µA
ID(lim) 1...8
1
1.3 2
A
ID(lim) 9...16
3
4
6
Tth(sd)
170 --
200
°C
Thys
--
10 --
K
6. SPI-Timing
Serial Clock Frequency (depending on SO load)
Serial Clock Period (1/fclk)
Serial Clock High Time
Serial Clock Low Time
Enable Lead Time (falling edge of CS to rising edge of
CLK)
Enable Lag Time (falling edge of CLK to rising edge of CS )
Data Setup Time (required time SI to falling of CLK)
Data Hold Time (falling edge of CLK to SI)
Disable Time @ CL = 50 pF5
Transfer Delay Time6
( CS high time between two accesses)
Data Valid Time
CL = 50 pF5
CL = 100 pF5
CL = 220 pF5
fSCK
tp(SCK)
tSCKH
tSCKL
tlead
tlag
tSU
tH
tDIS
tdt
tvalid
DC --
200 --
50 --
50 --
200 --
200 ---
20 --
20 --
--
--
200 --
--
--
--
--
--
--
5
MHz
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
150 ns
--
ns
100 ns
120
150
5 This parameter will not be tested but guaranteed by design
6 This time is necessary between two write accesses to control e.g. channel 1 to 8 during the first access and
channel 9 to 16 during the second access. To get the correct diagnostic information, the transfer delay time has
to be extended to the maximum fault delay time td(fault)max = 200µs.
V3.1
Page 6
26.Aug 2002