Data Sheet TLE 6240 GP
Detailed Block Diagram
All 16 channels can be controlled via the serial interface (SPI). In addition to the serial control it is possible to con-
VS
PRG
IN1
IN4
GND VS
AND or OR program-
mable via SPI ctrl. word
≥1
&
as channel 1
IN9
IN12
FAULT
RESET
SO
SI
SCLK
CS
as channel 1
as channel 1
8 bit
16 bit
DIAG
SPI
Interface
16 bit
8 bit
16 bit
DIAG
Normal function
SCB/Overload
Open load
Short to ground
Output Stage
OUT1
OUT4
OUT9
OUT12
Normal function
SCB/Overload
Open load
Short to ground
Output Stage
OUT5
OUT8
OUT13
OUT16
GND
trol channel 1 to 4 and 9 to 12 direct in parallel with a separate input pin. The parallel input signal is either ORed or
ANDed with the respective SPI data bit. This boolean operation can be programmed via SPI control byte (see
chapter "Functional Description"). The SPI interface also performs a diagnostic information for each channel.
V3.1
Page 2
26.Aug 2002