Data Sheet TLE 6240 GP
Maximum Ratings for Tj = – 40°C to 150°C
Parameter
Supply Voltage
Continuous Drain Source Voltage (OUT1...OUT16)
Input Voltage, All Inputs and Data Lines
Load Dump Protection VLoad Dump = UP+US; UP=13.5 V
RI1)=2 Ω; td=400ms; IN = low or high
Channel 1-8 with Automotive Relay RL = 65 Ω
Channel 9-16 with Automotive Injector Valve RL = 14 Ω
RI=2 Ω; td=400ms; IN = low or high
Channel 1-8 with Load RL = 24 Ω
Channel 9-16 with Load RL = 6.8 Ω
Output Current per Channel (see el. characteristics)
Output Current per Channel @ TA = 25°C
(All 16 Channels ON; Mounted on PCB ) 3)
Output Current
(Max. total current of all channels on; Heat Sink required)
Single Pulse Inductive Energy (internal clamping)
TJ = 25°C, ID1-8 = 0.5 A, ID9-16 = 1 A
Power Dissipation (DC, mounted on PCB) @ TA = 25°C
Electrostatic Discharge Voltage (Human Body Model)
according to MIL STD 883D, method 3015.7 and EOS/ESD
assn. standard S5.1 - 1993
DIN Humidity Category, DIN 40 040
IEC Climatic Category, DIN IEC 68-1
Thermal Resistance
junction - case (die soldered on heat slug)
junction - ambient @ min. footprint
junction - ambient @ 6 cm2 cooling area with heat pipes
Symbol Values
VS
-0.3 ... +7
VDS
45
VIN
VLoad Dump2)
- 0.3 ... + 7
Unit
V
V
V
V
90
65
ID(lim)
ID1-8
ID9-16
IDmax
65
50
ID(lim) min
A
0.3
A
0.5
14
A
EAS
50 mJ
Ptot
VESD
3.3 W
2000
V
RthJC
RthJA
E
40/150/56
1.5 K/W
50
38
Minimum footprint
PCB with heat pipes,
back side 6 cm2 cooling area
1)
2)
3)
RI=internal resistance of the load dump test pulse generator LD200
VLoadDump is setup without DUT connected to the generator per ISO 7637-1 and DIN 40 839.
Output current rating so long as maximum junction temperature is not exceeded. At TA = 125
°C
the
output
cur-
rent has to be calculated using RthJA according mounting conditions.
V3.1