English
Language : 

ICB2FL01G Datasheet, PDF (47/56 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
2nd Generation FL-Controller for FL-Ballasts
Electrical Characteristics
5.3.3 Inverter Section
5.3.3.1
Low Side Current Sense (LSCS)
Parameter
Overcurrent Shut Down Volt.
Overcurrent Shut Down Volt.
Duration of Overcurrent
Capacitive Mode Det. Level 1
Capacitive Mode Duration 1
Capacitive Mode Det. Level 2
Capacitive Mode Duration 2
Capacitive Mode Det. Level 3
Capacitive Mode Duration 3
LSCS Bias Current
Symbol
VLSCSOvC1
VLSCSOvC2
tLSCSOvC
VLSCSCap1
tLSCSCap1
VLSCSCap2
tLSCSCap2
VLSCSCap3
tLSCSCap3
ILSCSBias
Limit Values
min. typ. max.
1.5 1.6 1.7
0.75 0.8 0.85
450 600 700
80 100 123
— 280 —
1.8 2.0 2.2
—
50 —
- 120 - 100 - 77
— 280 —
-1.0 — 1.0
Unit
Test Condition
V
1)
V
2)
ns
mV During Run Mode
ns 3)
V During Run Mode
ns 4)
mV
ns 5)
µA @ VLSCS = 1.5V
1) Overcurrent Voltage Threshold active during: Start Up, Soft start, Ignition and Pre Run Mode
2) Overcurrent Voltage Threshold active during: Preheating and Run Mode
3) Active during 2nd 50% Duty Cycle of LSGD in Run Mode
4) Active during Turn ON of the HSGD in Run Mode
5) Active before Turn ON of the HSGD in Run Mode
Datasheet
Page 47 of 56
ICB2FL01G
V1.2