English
Language : 

ICB2FL01G Datasheet, PDF (35/56 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
2nd Generation FL-Controller for FL-Ballasts
2.8.2 Deactivation of the Filament Detection
Functional Description
In order to deactivate the filament detection of the low or high side filament, set the RES pin 12 or the
LVS1 / LVS2 pin 13 / 14 to GND. In that case, the IC starts up into normal operation without checking
the filaments e.g. when using an equivalent lamp resistive load instead of a load.
VCC
17.5 V
16.0 V
Chip Supply Voltage
14.1 V
10.6 V
Start Up
VRES UVLO Hysteresis
5.0 V
1.6 V
LVS1 or LVS2 PIN set to GND
1.3 V
VLSGD
10V
Time
VLamp
Figure 34: Deactivation via RES PIN
Figure 35: Deactivation via LVS1 / LVS2 PIN
Figure 34 shows the deactivation of the low and high side filament via set the RES pin 12 to GND.
Figure 35 shows the deactivation of the high side filament detection via set the LVS1 or LVS2 pin to
GND.
Note
In case using just one path of a ballast design (single or dual lamp in series) one of the not used LVS
pins has to be set to GND.
Datasheet
Page 35 of 56
ICB2FL01G
V1.2