English
Language : 

TLE6240GP_10 Datasheet, PDF (27/37 Pages) Infineon Technologies AG – Smart 16-Channel Low-Side Switch
TLE6240GP
Smart 16-Channel Low-Side Switch
Control of the Device
IN 1...4/9...12
≥1
Output
Driver
Serial Input,
data bits 0...3
Figure 19 OR Operation between IN and Serial Input
This OR operation enables the serial interface to switch the channel ON, even though the corresponding parallel
input might be in the off state.
SPI Priority for ON-State
Also parallel control of the outputs is possible without an SPI input.
The OR-function is the default Boolean operation if the device restarts after a Reset, or when the supply voltage
is switched on for the first time.
If the OR operation is programmed it is latched until it is overwritten by the AND operation.
6.1.5.5 Control Byte No. 5 and 10
Table 9
MSB
Control Byte No. 5 and 10
Comment
H
H
H
H
X
X
X
X AND operation, and ‘full diagnosis’
Control Byte
With HHHH LLLL as the control word, each of the input signals IN1 to IN4 are ‘AND’ed with the corresponding SI
data bits.
With HHHH HHHH as the control word, each of the input signals IN9 to IN12 are ‘AND’ed with the corresponding
SI data bits.
IN 1...4/9...12
&
Output
Driver
Serial Input,
data bits 0...3
Figure 20 AND Operation between IN and Serial Input
Data Sheet
27
Rev.3.3, 2010-02-15