TLE5010 Datasheet, PDF (19/56 Pages) Infineon Technologies AG – GMR Based Angular Sensor
TLE5010
Draft
Electrical and Magnetic Parameters
Orthogonality Definition
The corresponding maximum and zero crossing points of the SIN and COS signals are
not exactly in a distance of 90°. The difference between X and Y phase is called
’Orthogonality Error’.
ϕ = ϕX – ϕY
jideal = 0°
jX : Phase error of X (= cos) Signal
jY : Phase error of Y (= sin) Signal
5.4
Calibration
GMR Values
The end-of-line calibration can be done using following sequence.
The conditions are specified in Table 9.
• Turn magnetic field left and measure X and Y values
• Calculation of Amplitude, Offset, Phase correction values of left turn
• Turn further 90° left and 90° back right without measurement
• Turn magnetic field right and measure X and Y values
• Calculation of Amplitude, Offset, Phase correction values of right turn
• Calculation of mean values of Amplitude, Offset, Phase correction values
The above gained values have to be stored in a non-volatile memory. They are used for
the correction of the read-out X and Y values before the angular calculation.
The resulting angular deviation is calculated using above determined parameters.
Temperature Measurement
The signal amplitude T25 of the temperature measurement path at calibration conditions
has to be measured and stored.
Calibration Conditions
All errors are related to a calibration done using following conditions:
Table 9
GMR calibration conditions
Parameter
Symbol Limit Values
Unit Notes
min. typ. max.
Flux density
Temperature
BCAL -
TCAL
-
30
-
25
-
mT BZ = 0 mT
°C
Preliminary Data Sheet
19
V 0.9, 2007-05