English
Language : 

TLE5010 Datasheet, PDF (18/56 Pages) Infineon Technologies AG – GMR Based Angular Sensor
TLE5010
Draft
Electrical and Magnetic Parameters
Amplitude Definition
The amplitude is defined as half difference between the signed maximum and minimum
values of the idealized (fitted) sine or cosine wave.
AX
=
-X---M----A----X-----–----X----M----I--N-
2
AY
=
Y----M----A---X-----–-----Y---M----I--N--
2
Offset Definition
The offset of the X and Y signals is defined as the mean value between the signed
maximum and minimum values of the idealized (fitted) sine or cosine wave.
OX
=
-X---M----A----X-----+----X----M----I--N--
2
OY
=
-Y---M----A----X----+-----Y---M-----I-N--
2
Temperature dependent behavior
The temperature offset gradients for both channels depend on the value at 25°C. It can
be calculated using following linear equations:
KTOX = tco_d_x + (tco_k_x × OX25)
KTOY = tco_d_y + (tco_k_y × OY25)
OX25, OY25: Offset values at 25°C in digits.
.
Table 8
GMR Temperature Coefficients
Parameter
Symbol Limit Values
Unit
min. typ.
max.
Offset Temperature
Coefficient base
tco_d_x -
tco_d_y -
+0.116296 -
-0.079401 -
digits_/_K
Offset Temperature
Coefficient gain
tco_k_x -
tco_k_y -
-0.0010147 -
-0.0010121 -
1_/_K
Notes
Preliminary Data Sheet
18
V 0.9, 2007-05