English
Language : 

TLE6254-2G Datasheet, PDF (16/24 Pages) Infineon Technologies AG – Fault Tolerant Differential CAN-Transceiver
Final Data TLE 6254-2G
Static Characteristics
8
Static Characteristics (cont’d)
4.75 V ≤ VCC ≤ 5.25 V; 6 V ≤ VS ≤ 27 V; normal operation mode; – 40 ≤ Tj ≤ + 125 °C
(unless otherwise specified). All voltages are defined with respect to ground. Positive
current flowing into the IC.
Parameter
Symbol
Limit Values
Unit Notes
min. typ. max.
Voltage detection
Vdet(th) 6.5
7.3
8.0
V
–
threshold for short-circuit
to battery voltage on
CANH and CANL
Voltage detection
threshold for short-circuit
to battery voltage on
CANH
Vdet(th)
VBAT VBAT VBAT V
– 2.5 – 2 – 1
stand-by/
sleep operation
mode
CANH wake-up voltage VCANH,wu 1.2 1.9 2.7 V –
threshold
CANL wake-up voltage VCANL,wu 2.2 3.1 3.9 V –
threshold
Wake-up voltage
threshold hysteresis
CANH single-ended
receiver threshold
∆Vwu
0.2
–
–
V
∆Vwu = VCANL,wu –
VCANH,wu
VCANH 1.6 2.1 2.6 V failure cases 3, 5
and 7
CANL single-ended
receiver threshold
VCANL 2.4 2.9 3.4 V failure case 6 and
6a
CANL leakage current ICANL,lk – 5 0
5
µA VCC = 0 V;
VS = 0 V;
VCANL = 12 V;
Tj < 85 °C
CANH leakage current ICANH,lk – 5 0
5
µA VCC = 0 V;
VS = 0 V;
VCANH = 5 V;
Tj < 85 °C
Data Sheet Version 1.4
16
2003-07-22