English
Language : 

TLE6254-2G Datasheet, PDF (1/24 Pages) Infineon Technologies AG – Fault Tolerant Differential CAN-Transceiver
Fault Tolerant Differential CAN-Transceiver
TLE 6254-2G
Final Data Sheet
1
Features
• Data transmission rate up to 125 kBaud
• Very low current consumption in stand-by and sleep
operation mode
• Implemented receive-only mode
• Optimized EMC behavior
• Wake-up input pin, dual edge sensitive
P-DSO-14-13
• Battery fail flag
• Extended bus failure management to guarantee safe
operation during all bus line failure events
• Full support of dual failure conditions
• Fully wake-up capability during all bus line failures conditions
• Supports one-wire transmission mode with ground offset voltages up to 1.5 V
• Prevention from bus occupation in case of CAN controller failure
• Thermal protection
• Bus line error protection against transients in automotive environment
Type
TLE 6254-2G
Ordering Code
Q67006-A9549
Package
P-DSO-14-13 (SMD)
2
Description
The CAN-Transceiver TLE 6254-2G works as the interface between the CAN protocol
controller and the physical CAN bus-lines.
It is optimized for low-speed data transmission (up to 125 kBaud) in automotive and
industrial applications.
While no data is transferred, the power consumption can be minimized by multiple low
power modes.
In normal operation mode a differential signal is transmitted/received. When bus wiring
failures are detected the device automatically switches in a dedicated single-wire mode
to maintain communication.
Data Sheet Version 1.4
1
2003-07-22