English
Language : 

BTF50060-1TEA_11 Datasheet, PDF (14/38 Pages) Infineon Technologies AG – Smart High-Side Power Switch, One Channel
BTF50060-1TEA
Functional Description
5.1.3 Switching a Capacitive Load
A capacitive load’s dominant characteristic is it’s inrush current. The BTF50060-1TEA can support inrush currents
up to IL(SC). If the inrush current reaches IL(SC), the device may detect a short circuit condition and switches OFF.
For a description of the short circuit protection mechanism, please refer to Chapter 5.3.1.
5.1.4 Inverse Load Current Operation
In case of a negative load current, e.g. caused by load operating as a generator, the device can not block a current
flowing through the intrinsic body diode. See Figure 13. The power stage of the device can be switched ON or
stays ON as long as VIN = HIGH, reaching the same RDS(ON) as for positive load currents, if no fault condition is
detected. In case of fault condition, the logic of the device will switch OFF the power stage and supply a fault signal
IIS(fault). Since the device can not block a negative load current (even under fault conditions), it can not protect itself
from overload condition. In the application, overload conditions, e.g. over temperature, must not occur during
inverse load current operation.
VS
-IL(inv)
OUT
GND
G
Figure 13 Inverse load current operation
In ve r s.e m f
5.2
Input Circuit
The input circuitry is compatible with 3.3 and 5V micro controllers. If VIN is set to VIN = VIN(H) (VIN = HIGH), the
device will turn ON. See Figure 10 for the timings. If VIN is set to VIN = VIN(L) (VIN = LOW), the power stage of the
device will be turned OFF. The input circuitry has a hysteresis ΔVIN. The input circuitry is compatible with PWM
applications. Figure 14 shows the electrical equivalent input circuitry. The logic of the BTF50060-1TEA stays
active for a delay time tRESET after the switch OFF signal.
IN
RIN
Figure 14 Input pin circuitry
GND
InputCircuitry.emf
Applying an input voltage of VIN > 20V (absolute maximum ratings exceeded!) may force the BTF50060-1TEA to
deactivate parts of the logic circuitry. This includes the undervoltage shutdown, the undervoltage restart delay, and
the analog sense function. In this case, also the short circuit shutdown threshold IL(SC) is set to typically 50A, and
Datasheet
Speed PROFETTM
14
Rev. 1.2, 2011-09-01