English
Language : 

SLB9660 Datasheet, PDF (13/22 Pages) Infineon Technologies AG – Trusted Platform Module
SLB 9660 TPM1.2
Trusted Platform Module
Electrical Characteristics
5
Electrical Characteristics
This chapter lists the maximum and operating ranges for various electrical and timing parameters.
5.1
Absolute Maximum Ratings
Table 5-1 Absolute Maximum Ratings
Parameter
Symbol
Min.
Supply Voltage
VDD
-0.3
Voltage on any pin
Vmax
-0.3
Ambient temperature TA
-20
Ambient temperature TA
-40
Storage temperature TS
-40
ESD robustness HBM: VESD,HBM
–
1.5 kΩ, 100 pF
ESD robustness
VESD,CDM
–
Values
Typ. Max.
–
3.6
–
VDD+0.3
–
85
–
85
–
125
–
2000
–
500
Latchup immunity
Ilatch
100
Unit Note or Test Condition
V
–
V
–
°C Standard temperature devices
°C Enhanced temperature devices
°C –
V
According to EIA/JESD22-A114-B
V
According to ESD Association
Standard STM5.3.1 - 1999
mA According to EIA/JESD78
Attention: Stresses above the max. values listed here may cause permanent damage to the device.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability. Maximum ratings are absolute ratings; exceeding only one of these values may
cause irreversible damage to the integrated circuit.
5.2
Functional Operating Range
Table 5-2 Functional Operating Range
Parameter
Symbol
Values
Unit Note or Test Condition
Min. Typ. Max.
Supply Voltage
VDD
Ambient temperature TA
Ambient temperature TA
Useful lifetime1)
Operating lifetime1)
3.0 3.3 3.6
-20 –
85
-40 –
85
–
–
5
–
–
5
V
–
°C Standard temperature devices
°C Enhanced temperature devices
y
y
Average TA over lifetime
–
55 –
°C
1) The useful lifetime of the device is 5 (five) years with a duty cycle (that means, a power-on time) of 100%. An useful
lifetime of 7 (seven) years can be guaranteed for a duty cycle of 70%. For both scenarios, it is assumed that the device
will be used for calculations for approximately 5% of the maximum useful lifetime.
Data Sheet
13
Revision 1.0 2014-12-12