English
Language : 

ICS851S201I Datasheet, PDF (5/17 Pages) Integrated Device Technology – 2:1 Differential-to-HCSL Multiplexer with Low Input Level Alarm
ICS851S201I Data Sheet
2:1 DIFFERENTIAL-TO-HCSL MULTIPLEXER
AC Electrical Characteristics
Table 5. AC Characteristics, VDD = 3.3V±5%; TA = -40°C to 85°C
Symbol
Parameter
Test Conditions
fOUT
tPD
Output Frequency
Propagation Delay;
NOTE 1
tsk(pp)
Part-to-Part Skew;
NOTE 2, 3
tsk(o)
Output Skew,
Note 2, 4
tjit
Buffer Additive Phase Jitter,
RMS
133.33MHz, Integration Range:
12kHz - 20MHz
Rise/Fall Edge Rate;
NOTE 5, 6
VMAX
Absolute Max Output Voltage;
NOTE 7, 8
VMIN
Absolute Min Output Voltage
NOTE 7, 9
VCROSS
Absolute Crossing Voltage;
NOTE 7, 10, 11
VCROSS
Total Variation of VCROSS over
all edges; NOTE 7, 10, 12
odc
Output Duty Cycle
MUXISOL
MUX Isolation; NOTE 13
ƒOUT  100MHz
Minimum
1.24
1.60
-300
250
47
-65
Typical
1.4
5
0.151
2.56
50
-63
Maximum
250
1.70
Units
MHz
ns
150
ps
34
ps
0.166
ps
3.74
V/ns
1150
mV
mV
550
mV
140
mV
53
%
-62
dB
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the device
is mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after thermal
equilibrium has been reached under these conditions.
NOTE: All parameters measured at ƒ  250MHz unless otherwise noted.
NOTE 1: Measured from the differential input crossing point to the differential output crossing point.
NOTE 2: This parameter is defined in accordance with JEDEC Standard 65.
NOTE 3: Defined as skew between outputs on different devices operating at the same supply voltage, same temperature, same frequency
and with equal load conditions. Using the same type of inputs on each device, the outputs are measured at the differential cross points.
NOTE 4: Defined as skew between outputs at the same supply voltages and with equal load conditions. Measured at the output differential
cross points.
NOTE 5: Measurement taken from differential waveform.
NOTE 6: Measured from -150mV to +150mV on the differential waveform (derived from Qx minus nQx). The signal must be monotonic
through the measurement region for rise and fall time. The 300mV measurement window is centered on the differential zero crossing.
See Parameter Measurement Information Section.
NOTE 7: Measurement taken from single ended waveform.
NOTE 8: Defined as the maximum instantaneous voltage including overshoot. See Parameter Measurement Information Section.
NOTE 9: Defined as the minimum instantaneous voltage including undershoot. See Parameter Measurement Information Section.
NOTE 10: Measured at crossing point where the instantaneous voltage value of the rising edge of Qx equals the falling edge of nQx.
See Parameter Measurement Information Section
NOTE 11: Refers to the total variation from the lowest crossing point to the highest, regardless of which edge is crossing. Refers to all crossing
points for this measurement. See Parameter Measurement Information Section.
NOTE 12: Defined as the total variation of all crossing voltage of rising Qx and falling nQx. This is the maximum allowed variance in the
VCROSS for any particular system. See Parameter Measurement Information Section.
NOTE 13: Qx, nQx output measured differentially. See Parameter Measurement Information for MUX Isolation diagram.
ICS851S201CKI MAY 27, 2017
5
©2017 Integrated Device Technology, Inc.