English
Language : 

ICS932S203 Datasheet, PDF (12/18 Pages) Integrated Circuit Systems – Frequency Generator with 133MHz Differential CPU Clocks
ICS932S203
Frequency Generator with 133MHz Differential CPU Clocks
General SMBus serial interface information
The information in this section assumes familiarity with SMBus programming.
For more information, contact ICS for an SMBus software program.
How to Write:
• Controller (host) sends a start bit.
• Controller (host) sends the write address D2 (H)
• ICS clock will acknowledge
• Controller (host) sends a dummy command code
• ICS clock will acknowledge
• Controller (host) sends a dummy byte count
• ICS clock will acknowledge
• Controller (host) starts sending first byte (Byte 0)
through byte 5
• ICS clock will acknowledge each byte one at a time.
• Controller (host) sends a Stop bit
How to Read:
• Controller (host) will send start bit.
• Controller (host) sends the read address D3 (H)
• ICS clock will acknowledge
• ICS clock will send the byte count
• Controller (host) acknowledges
• ICS clock sends first byte (Byte 0) through byte 6
• Controller (host) will need to acknowledge each byte
• Controller (host) will send a stop bit
How to Write:
Controller (Host)
Start Bit
A ddres s
D2(H )
ICS (Slave/Receiver)
ACK
Dummy Command Code
ACK
Dummy Byte Count
ACK
Byte 0
ACK
Byte 1
ACK
Byte 2
ACK
Byte 3
ACK
Byte 4
ACK
Byte 5
ACK
Byte 6
ACK
Stop Bit
How to Read:
Controller (Host)
ICS (Slave/Receiver)
Start Bit
A ddres s
D3(H )
ACK
Byte Count
ACK
Byte 0
ACK
Byte 1
ACK
ACK
ACK
ACK
ACK
ACK
Stop Bit
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Notes:
1.
The ICS clock generator is a slave/receiver, SMBus component. It can read back the data stored in the latches for
verification. Read-Back will support Intel PIIX4 "Block-Read" protocol.
2.
The data transfer rate supported by this clock generator is 100K bits/sec or less (standard mode)
3.
The input is operating at 3.3V logic levels.
4.
The data byte format is 8 bit bytes.
5.
To simplify the clock generator SMBus interface, the protocol is set to use only "Block-Writes" from the controller. The
bytes must be accessed in sequential order from lowest to highest byte with the ability to stop after any complete byte
has been transferred. The Command code and Byte count shown above must be sent, but the data is ignored for those
two bytes. The data is loaded until a Stop sequence is issued.
6.
At power-on, all registers are set to a default condition, as shown.
IDTTM Frequency Generator with 133MHz Differential CPU Clocks
12
0601G—01/26/10