English
Language : 

IC-MHL200 Datasheet, PDF (28/33 Pages) IC-Haus GmbH – 12-BIT LINEAR / ROTARY POSITION HALL ENCODER
iC-MHL200
12-BIT LINEAR / ROTARY POSITION HALL ENCODER
Rev C1, Page 28/33
CFGTOB
CFGTOS
CFGTOS
0
1
x
Addr. 0x04; bit 4
Addr. 0x7C; bit 0
CFGTOB
0
0
1
Timeout
16 µs
2 µs
2 µs
Table 32: BiSS timeout for sensor data
The BiSS timeout can be programmed to a shorter
value with the CFGTOS bit. However, this setting is
reset to the default value 16 µs again following a reset.
The BiSS timeout can be permanently programmed for
faster data transmission with the CFGTOB register via
a zapping diode. Resetting to slower data transmission
is then not possible.
The registers 0x78 to 0x7F are reserved for the BiSS
Identifier. The BiSS Identifier identifies the device man-
ufacturer and the type of BiSS module. The registers
0x7D to 0x7F are alterable and programmable to pro-
vide a manufacturer individual BiSS Device Manufac-
turer ID and revision.
OEM DATA
Parameters OEMA, OEMB and OEMC can be used
and zapped as user specific data. OEMRAM can not
be zapped.
Parameter
OEMA
OEMB
OEMC
OEMRAM
Address
0x0A; bit 7:4
0x0B; bit 7:0
0x0C; bit 7:0
0x0D; bit 7:0
Zapping possible
yes
yes
yes
no
Table 33: Overview of OEM Data