Time base scale calibration steps
Rev B1, Page 13/22
Time base linearity calibration steps
1. Make sure that scope was powered on for mini-
mum 10 minutes
2. Open Calibration - Edit Calibration Data
3. Press the ”Set for Cal GL” button and follow the
instructions
1. Make sure that scope was powered on for mini-
mum 10 minutes
2. Open Calibration - Edit Calibration Data
Figure 32: Time base calibration
4. Press the ”Cal. Time base scale” button
5. Press ”Write Cal. To iC227 flash memory” button
Figure 34: Time base calibration
3. Press the ”Set for Linearity Calibration” button
and follow the instructions. The status of the cal-
ibration is shown inside the message window.
Figure 33: Write calibration data
Figure 35: Calibration status