iC-MA3 ANGULAR HALL SENSOR
WITH SIN/COS OUTPUT, CASCADABLE
Rev A2, Page 10/19
Output level setting
In any case Vref, the half of the supply voltage, remains
Pin ASEL selects the target amplitude to which the to be the reference voltage.
sin/cos signals output at ports P0 to P3 are regulated to.
Mode
High-Level Output
Mid-Level Output
Low-Level Output
ASEL
high
low
open
Signal Amplitude
±1000 mV
±500 mV
±250 mV
Notes
V(P0. . . P3) =
Vref ±Vout()pk
Table 7: Output level setting
Standby
If pin NEN, featuring an internal pull-up, is not forced
low by an external signal, iC-MA3 remains in standby
mode. During this mode the tri-level mode control in-
puts M0, M1, PSEL, ASEL, FSEL, and the signal ports
P0 to P3 are all high impedance, so that a minimal
current consumption is obtained.
Mode
Standby
NEN
high
Mode Control Inputs
M0, M1, PSEL, ASEL, FSEL
high impedance
Signal Ports
P0, P1, P2, P3,
GAIN, NERR
high impedance1
Notes
Table 8: Standby
1 During chain operation, pin P3 remains active high to disable the subsequent IC.
Test Mode
With pin NTM, iC-MA3 can be set to test mode for
iC-Haus device testing. If there is no external signal
forcing pin NTM low, the pin’s internal pull-up disables
the test mode. However, for safety pin NTM should be
connected to VDD to avoid any unwanted function.
Mode
NTM
Test Mode low
Mode Control Inputs
M0, M1, PSEL, ASEL, FSEL
Signal Ports
P0. . . P3
Notes
device test only
Table 9: Test mode