English
Language : 

HCPL-3120 Datasheet, PDF (4/15 Pages) Agilent(Hewlett-Packard) – 2.0 Amp Output Current IGBT Gate Drive Optocoupler
Insulation and Safety Related Specifications
Parameter
Symbol Value Units
Conditions
Minimum External Air
Gap (External
Clearance)
L(101)
7.1 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External
Tracking (External
Creepage)
L(102)
7.4 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic
Gap (Internal Clearance)
0.08 mm Insulation thickness between emitter and detector;
also known as distance through insulation.
Tracking Resistance
CTI
200 Volts DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking
Index)
Isolation Group
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Average Input Current
Peak Transient Input Current
(<1 µs pulse width, 300 pps)
Reverse Input Voltage
“High” Peak Output Current
“Low” Peak Output Current
Supply Voltage
Output Voltage
Output Power Dissipation
Total Power Dissipation
Lead Solder Temperature
Solder Reflow Temperature Profile
Symbol
TS
TA
IF(AVG)
Min.
-55.
-40
Max.
125
100
25
Units
°C
°C
mA
Note
1
IF(TRAN)
1.0
A
VR
5
Volts
IOH(PEAK)
2.5
A
2
IOL(PEAK)
2.5
A
2
(VCC - VEE)
0
35
Volts
VO
0
VCC
Volts
PO
250
mW
3
PT
295
mW
4
260°C for 10 sec., 1.6 mm below seating plane
See Package Outline Drawings section
Recommended Operating Conditions
Parameter
Power Supply Voltage
Input Current (ON)
Input Voltage (OFF)
Operating Temperature
Symbol
(VCC - VEE)
IF(ON)
VF(OFF)
TA
Min.
15
7
-3.0
-40
Max.
30
16
0.8
100
Units
Volts
mA
V
°C
1-185