English
Language : 

HCPL-7860 Datasheet, PDF (3/28 Pages) Agilent(Hewlett-Packard) – Isolated 15-bit A/D Converter
isolated modulator without
additional hardware. Because the
two inputs are multiplexed, only
one conversion at a time can be
made and not all features are
available for the second channel.
The available features for both
channels are shown in the table
at right.
HCPL-x870 Digital Interface IC
Feature
Conversion Mode
Offset Calibration
Pre-Trigger Mode
Over-Range Detection
Adjustable Threshold Detection
Channel #1





Channel #2


Functional Diagrams
ISOLATION
BOUNDARY
VDD1 1
8 VDD2
VIN+ 2
VIN– 3
SIGMA-
DELTA
MOD./
ENCODE
7 MCLK
DECODE
6 MDAT
GND1 4
SHIELD
5 GND2
HCPL-7860 Isolated Modulator
CCLK 1
CLAT 2
CDAT 3
MCLK1 4
MDAT1 5
MCLK2 6
MDAT2 7
GND 8
CONFIG.
INTER-
FACE
CON-
VERSION
INTER-
FACE
CH1
16 VDD
15 CHAN
14 SCLK
13 SDAT
12 CS
THRES- 11 THR1
HOLD
CH2 DETECT 10 OVR1
&
RESET 9 RESET
HCPL-x870 Digital Interface IC
Pin Description, Isolated Modulator
Symbol
Description
VDD1
VIN+
Supply voltage input (4.5 V to 5.5 V)
Positive input (± 200 mV
recommended)
VIN– Negative input
(normally connected to GND1)
GND1 Input ground
Symbol
VDD2
MCLK
Description
Supply voltage input (4.5 V to 5.5 V)
Clock output (10 MHz typical)
MDAT Serial data output
GND2 Output ground
1-262