English
Language : 

RFM22 Datasheet, PDF (119/150 Pages) –
RFM22
The total settling time (cold start) of the PLL after the calibration can be calculated as TCS = TS + TO.
Register 53h. PLL Tune Time
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
pllts[4:0]
pllt0
Type
R/w
R/w
Reset value = 01010010
Bit
Name
7:3
pllts[4:0]
2:0
pllt0
Function
PLL Soft Settling Time (TS).
This register will set the settling time for the PLL from a previous locked
frequency in Tune mode. The value is configurable between 0 μs and 310 μs,
in 10 μs intervals. The default plltime corresponds to 100 μs. See formula
above.
PLL Settling Time (TO).
This register will set the time allowed for PLL settling after the calibrations are
completed. The value is configurable between 0 μs and 70 μs, in 10 μs steps.
The default pllt0 corresponds to 20 μs. See formula above.
119
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com