FX11 Seriesq0.5mm Pitch Connectors with Ground Plate for 2mm to 3mm Board-to-Board Connections
sHeader with ground plate
q 3mm stacking height
(0.5)
A±0.2
0.5±0.05
0.2±0.05
(0.75)
(0.75)
(6)
B±0.2
C±0.3
2-(Ø0.8)
Guidepost
D±0.1
Unit : mm
Part Number
CL No.
Number of contacts
A BCDE F
Signal Ground
Remarks
RoHS
FX11A- 60P/ 6-SV0.5(71) 573-0602-4-71
60
FX11A- 80P/ 8-SV0.5(71) 573-0603-7-71
80
6 17.5 12 22.6 18 19.4 25.5
8
23.5 18 28.6 24 25.4 31.5 With guideposts
FX11A-100P/10-SV0.5(71) 573-0604-0-71 100
FX11B- 60P/ 6-SV0.5(71) 573-0612-8-71
60
FX11B- 80P/ 8-SV0.5(71) 573-0613-0-71
80
10 29.5 24 34.6 30 31.4 37.5
YES
6 17.5 12 22.6 ---------- 19.4 25.5
8
23.5 18 28.6 ---------- 25.4 31.5 Without guideposts
FX11B-100P/10-SV0.5(71) 573-0614-3-71 100
10 29.5 24 34.6 ---------- 31.4 37.5
[Specifications number] – **, (**)
(71): Tray packaging (Without pick-and-place tape)
(91) : Embossed tape packaging (Without pick-and-place tape)
(92) : Embossed tape packaging (With pick-and-place tape)
Note 1: There is no polarity in terms of board mounting for this product.
Note 2: The coplanarity of this product's SMT leads is 0.1 mm or less.
Note 3: Please order embossed tape packaged items by the reel. (One reel holds 1,000 pieces.)
BRecommended Land Pattern Dimensions (Metal Mask Dimensions)
4 Fmin
Recommended metal mask thickness: 0.15 mm
C +0.1
0
E0
-0.1
D±0.05
A±0.05
0.5 ±0.03
0.75 ±0.03
0.75 ±0.03
3 Ø0.9 ±0.05
0.25 ±0.05
3 ±0.05
1 6 ±0.05 0.7±0.03 (Land)
0.6±0.03(Metal mask)
B±0.05
Ø1±0.05 3
0.3±0.03 (Land)
0.25±0.03(Metal mask)
Note 1 Cross-hatched portions, totaling n places, indicate the ground circuits.
2 The cross-hatched area inside the SMT land may come into contact with the connector contacts
and thus care should be taken that the pattern does not extend beyond the SMT land width.
3 Not required in products without guideposts.
4 Do not mount a part other than this product in the area of . Doing so will prevent the engagement
of this and the mating connector.