Table 5-1: Register Descriptions - Standard Address Space (Continued)
Address Register Name Parameter Name
DDO1_SWING_BYPASS
1Fh
DRIVER_CONTROL_
REG_6
DDO1_SWING_MUTE
DDO1_SWING_5G94
DDO1_SWING_2G97
RSVD
20h
RECLOCKER_
BYPASS
MANUAL_BYPASS
AUTO_BYPASS
RSVD
21h
PD_CONTROL
LOCK_SAMPLE
RSVD
POLARITY_INVERT
Bit
Slice
R/W
Reset
Value
Description
15:12 RW
11:8 RW
7:4 RW
3:0 RW
15:2 RW
1:1 RW
0:0 RW
15:7 RW
6:6 RW
5:1 RW
0:0 RW
Differential swing (amplitude) control for
unlocked signals output on DDO1 (when
reclocker is operating in BYPASS mode). For
3h details refer to Section 4.5.3.
Also applies when the device is not locked.
Takes precedence over rate-specific swing
controls
Differential static amplitude control for
DDO1 when the output is muted. For details
3h refer to Section 4.5.3.
Takes precedence over rate-specific swing
controls and bypass swing control
Differential swing (amplitude) control for
3h 5.94Gb/s (6G UHD-SDI) signals output on
DDO1. For details refer to Section 4.5.3.
Differential swing (amplitude) control for
3h 2.97Gb/s (3Gb/s SDI) signals output on
DDO1. For details refer to Section 4.5.3.
0h Reserved. Do not change.
Used to manually bypass the retiming block
in the reclocker.
0b: Retimer not bypassed
0h 1b: Retimer bypassed
The assertion of MANUAL_BYPASS takes
precedence irrespective of the setting of
AUTO_BYPASS
Selects between automatic and manual
bypass of the retiming block when the
reclocker is not locked.
1h
0b: Auto-Bypass is disabled
1b: Auto-Bypass is enabled
Even if AUTO_BYPASS is asserted, the
assertion of MANUAL_BYPASS will still cause
the retimer to be bypassed.
1h Reserved. Do not change.
Selects sampling method for LOCK
DETECTION
0h 0b: Strict sampling
1b: High-jitter sampling
2h Reserved. Do not change.
0h —
GS6150
Final Data Sheet
PDS-060127
Rev.2
March 2015
www.semtech.com
53 of 64
Proprietary & Confidential