MB85RC64APNF-G Datasheet, PDF (10/32 Pages) Fujitsu Component Limited. – 64 K (8 K × 8) Bit I2C
MB85RC64A
• Sequential Read
Data can be received continuously following the Device address word (R/W “1” input) after specifying the
address in the same way as for Random Read. If the read reaches the end of address, the internal read
address automatically rolls over to first memory address 0000H and keeps reading.
...
A
Read
Data 8bits
A
Read
Data
... A
Read
Data 8bits
NP
Access from master
Access from slave
P Stop Condition
A ACK (SDA is the "L" level)
N NACK (SDA is the "H" level)
■ SOFTWARE RESET SEQUENCE OR COMMAND RETRY
In case the malfunction has occurred after power on, the master side stopped the I2C communication during
processing, or unexpected malfunction has occurred, execute the following (1) software recovery sequence
just before each command, or (2) retry command just after failure of each command.
(1) Software Reset Sequence
Since the slave side may be outputting “L” level, do not force to drive “H” level, when the master side drives
the SDA port. This is for preventing a bus conflict. The additional hardware is not necessary for this software
reset sequence.
9 set of “Start Conditions and one “1” data”
SCL
SDA
Hi-Z state by pull up Resistor
Send “Start Condition and one data “1”” .
Repeat these 9 times just before Write or Read command.
(2) Command Retry
Command retry is useful to recover from failure response during I2C communication.