Supply Current Characteristics
Table 7. Supply Current Characteristics (continued)
Num C
Parameter
Symbol VDD (V) Typical1 Max2
Unit
P Stop3 mode supply current
7P
D
D
–40 to 85 °C
5
–40 to 125 °C
S3I
–40 to 85 °C
DD
–40 to 125 °C
3
2
18.4
100
μA
16.82
1.97
90
8
D PRACMP (PRG disabled) adder to stop3,
D 25 °C
—
5
28.87
—
nA
3
27.06
—
nA
9
D PRACMP (PRG enabled) adder to stop3,
D 25 °C
—
5
79.42
—
nA
3
57.4
—
nA
D
10
ADC adder to stop2 or stop3, 25 °C
D
5
25
—
nA
—
3
6
—
nA
D
11
LVD adder to stop3 (LVDE = LVDSE = 1)
D
5
83.52
—
nA
—
3
83.52
—
nA
12
D Adder to stop3 for oscillator enabled
D (IREFSTEN = 1)
5
0.03
—
μA
—
3
0.01
—
μA
D TPM1 and TPM2 adder to run mode, 25 °C
13
D (CPU clock = 40 MHz, fBus = 20 MHz)
—
5
0.16
—
mA
3
0.18
—
mA
D PWT1 and PWT2 adder to run mode, 25 °C
14
D (CPU clock = 40 MHz, fBus = 20 MHz)
—
5
0.43
—
mA
3
0.41
—
mA
D PRACMP adder to run mode, 25 °C
15
D (CPU clock = 40 MHz, fBus = 20 MHz)
5
0.35
—
mA
—
3
0.35
—
mA
D MTIM1 and MTIM2 adder to run mode, 25 °C
16
D (CPU clock = 40 MHz, fBus = 20 MHz)
—
5
0.26
—
mA
3
0.24
—
mA
D ADC adder to run mode, 25 °C
17
D (CPU clock = 40 MHz, fBus = 20 MHz)
5
0.42
—
mA
—
3
0.32
—
mA
D IIC adder to run mode, 25 °C
18
D (CPU clock = 40 MHz, fBus = 20 MHz)
5
0.56
—
mA
—
3
0.53
—
mA
1 Typicals are measured at 25 °C.
2 Values given here are preliminary estimates prior to completing characterization.
3 All modules except ADC active, and does not include any dc loads on port pins.
4 Most customers are expected to find that the auto-wakeup from a stop mode can be used instead of the higher current wait mode.
MC9S08SF4 Series MCU Data Sheet, Rev. 2
Freescale Semiconductor
15