English
Language : 

XR19L212 Datasheet, PDF (35/52 Pages) Exar Corporation – TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L212
REV. 1.0.0
TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
EMSR[5:4]: Extended RTS Hysteresis
TABLE 13: AUTO RTS HYSTERESIS
EMSR
BIT-5
EMSR
BIT-4
FCTR
BIT-1
FCTR
BIT-0
RTS#
HYSTERESIS
(CHARACTERS)
0
0
0
0
0
0
0
0
1
±4
0
0
1
0
±6
0
0
1
1
±8
0
1
0
0
±8
0
1
0
1
±16
0
1
1
0
±24
0
1
1
1
±32
1
0
0
0
±40
1
0
0
1
±44
1
0
1
0
±48
1
0
1
1
±52
1
1
0
0
±12
1
1
0
1
±20
1
1
1
0
±28
1
1
1
1
±36
EMSR[6]: LSR Interrupt Mode
• Logic 0 = LSR Interrupt Delayed (for 16C2550 compatibility, default). LSR bits 2, 3, and 4 will generate an
interrupt when the character with the error is in the RHR.
• Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is
received into the FIFO.
EMSR[7]: 16X Sampling Rate Mode
Logic 0 = 8X Sampling Rate.
Logic 1 = 16X Sampling Rate (default).
4.12 FIFO Level Register (FLVL) - Read-Only
The FIFO Level Register replaces the Scratchpad Register (during a Read) when FCTR[6] = 1. Note that this is
not identical to the FIFO Data Count Register which can be accessed when LCR = 0xBF.
FLVL[7:0]: FIFO Level Register
This register provides the FIFO counter level for the RX FIFO or the TX FIFO or both depending on EMSR[1:0].
See Table 12 for details.
4.13 Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write
These registers make-up the value of the baud rate divisor. The concatenation of the contents of DLM and
DLL is a 16-bit value is then added to DLD/16 to achieve the fractional baud rate divisor. DLD must be enabled
via EFR bit-4 before it can be accessed. SEE ”PROGRAMMABLE BAUD RATE GENERATOR WITH
FRACTIONAL DIVISOR” ON PAGE 10.
4.14 Device Identification Register (DVID) - Read Only
This register contains the device ID (0x0A for XR16V2751). Prior to reading this register, DLL and DLM should
be set to 0x00 (DLD = 0xXX).
35