5.3 Receiver
The receiver section contains an 8-bit Receive Shift Register (RSR) and Receive Holding Register (RHR). The
RSR uses the 16X or 8X clock for timing. It verifies and validates every bit on the incoming character in the
middle of each data bit. On the falling edge of a start or false start bit, an internal receiver counter starts
counting at the 16X or 8X clock rate. After 8 or 4 clocks the start bit period should be at the center of the start
bit. At this time the start bit is sampled and if it is still a logic 0 it is validated. Evaluating the start bit in this
manner prevents the receiver from assembling a false character. The rest of the data bits and stop bits are
sampled and validated in this same manner to prevent false framing. If there were any error(s), they are
reported in the LSR register bits 1- 4. Upon unloading the receive data byte from RHR, the receive FIFO
pointer is bumped and the error flags are immediately updated to reflect the status of the data byte in RHR
register. RHR can generate a receive data ready interrupt upon receiving a character or delay until it reaches
the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a receive data ready time-out
function when receive data does not reach the receive FIFO trigger level. This time-out delay is 4 word lengths
as defined by LCR[1:0] plus 12 bits time. The RHR interrupt is enabled by IER bit-0.
5.3.1 Receive Holding Register (RHR)
The receive holding register is an 8-bit register that holds a receive data byte from the receive shift register
(RSR). It provides the receive data interface to the host processor. The host reads the receive data byte on this
register whenever a data byte is transferred from the RSR. RHR also part of the receive FIFO of 64 bytes by
11-bit wide, 3 extra bits are for the error flags to be in LSR register. When the FIFO is enabled by FCR bit-0, it
acts as the first-out register of the FIFO as new data are put over the first-in register. The receive FIFO pointer
is bumped after the RHR register is read. Also, the error flags associated with the data byte are immediately
updated onto the line status register (LSR) bits 1-4.
5.3.2 Receiver Operation in non-FIFO Mode
FIGURE 14. RECEIVER OPERATION IN NON-FIFO MODE
16X or 8X Clock
(8XMODE Register)
Receive Data Shift Data Bit
Register (RSR)
Validation
Receive Data Characters
Receive
Data Byte
and Errors
Error
Flags in
LSR bits
4:2
Receive Data
Holding Register
(RHR)
RHR Interrupt (ISR bit-2)
RXFIFO1