English
Language : 

XR16L2550IM-F Datasheet, PDF (30/44 Pages) Exar Corporation – LOW VOLTAGE DUART WITH 16-BYTE FIFO
XR16L2550
LOW VOLTAGE DUART WITH 16-BYTE FIFO
REV. 1.1.3
MSR[0]: Delta CTS# Input Flag
• Logic 0 = No change on CTS# input (default).
• Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[1]: Delta DSR# Input Flag
• Logic 0 = No change on DSR# input (default).
• Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
MSR[2]: Delta RI# Input Flag
• Logic 0 = No change on RI# input (default).
• Logic 1 = The RI# input has changed from a logic 0 to a logic 1, ending of the ringing signal. A modem status
interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[3]: Delta CD# Input Flag
• Logic 0 = No change on CD# input (default).
• Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem
status interrupt will be generated if MSR interrupt is enabled (IER bit-3).
MSR[4]: CTS Input Status
Normally this bit is the compliment of the CTS# input. However in the loopback mode, this bit is equivalent to
the RTS# bit in the MCR register. The CTS# input may be used as a general purpose input when the modem
interface is not used.
MSR[5]: DSR Input Status
Normally this bit is the compliment of the DSR# input. In the loopback mode, this bit is equivalent to the DTR#
bit in the MCR register. The DSR# input may be used as a general purpose input when the modem interface is
not used.
MSR[6]: RI Input Status
Normally this bit is the compliment of the RI# input. In the loopback mode this bit is equivalent to bit-2 in the
MCR register. The RI# input may be used as a general purpose input when the modem interface is not used.
MSR[7]: CD Input Status
Normally this bit is the compliment of the CD# input. In the loopback mode this bit is equivalent to bit-3 in the
MCR register. The CD# input may be used as a general purpose input when the modem interface is not used.
4.10 Scratch Pad Register (SPR) - Read/Write
This is a 8-bit general purpose register for the user to store temporary data. The content of this register is
preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle.
4.11 Baud Rate Generator Registers (DLL and DLM) - Read/Write
The Baud Rate Generator (BRG) is a 16-bit counter that generates the data rate for the transmitter. The rate is
programmed through registers DLL and DLM which are only accessible when LCR bit-7 is set to ‘1’.
SEE”PROGRAMMABLE BAUD RATE GENERATOR” ON PAGE 10. for more details.
4.12 Device Identification Register (DVID) - Read Only
This register contains the device ID (0x02 for XR16L2550). Prior to reading this register, DLL and DLM should
be set to 0x00.
30