English
Language : 

XR16C2550 Datasheet, PDF (26/38 Pages) Exar Corporation – 2.97V TO 5.5V DUART WITH 16-BYTE FIFO
XR16C2550
2.97V TO 5.5V DUART WITH 16-BYTE FIFO
xr
REV. 1.0.1
AC ELECTRICAL CHARACTERISTICS
TA=-40O TO +85OC, VCC = 2.97V TO 5.5V, 70 PF LOAD WHERE APPLICABLE
SYMBOL
PARAMETER
-
CLK
OSC
TAS
TAH
TCS
TRD
TDY
Crystal Frequency
Clock Pulse Duration
External Clock Frequency
Address Setup Time
Address Hold Time
Chip Select Width
IOR# Strobe Width
Read or Write Cycle Delay
3.3
LIMITS
MIN
MAX
20
17
30
5
10
70*
70*
70*
5.0
LIMITS
MIN
MAX
24
8
64
0
5
40
40
40
TRDV Data Access Time
35
25
TDD Data Disable Time
0
25
0
15
TWR IOW# Strobe Width
40
25
TDS Data Setup Time
20
15
TDH Data Hold Time
5
5
TWDO Delay From IOW# To Output
50
40
TMOD Delay To Set Interrupt From MODEM
Input
40
35
TRSI Delay To Reset Interrupt From IOR#
40
35
TSSI Delay From Stop To Set Interrupt
1
1
TRRI Delay From IOR# To Reset Interrupt
45
40
TSI Delay From Start To Interrupt
45
40
TINT Delay From Initial INT Reset To Transmit
8
24
8
24
Start
TWRI Delay From IOW# To Reset Interrupt
45
40
TSSR Delay From Stop To Set RXRDY#
1
1
TRR Delay From IOR# To Reset RXRDY#
45
40
TWT Delay From IOW# To Set TXRDY#
45
40
TSRT
Delay From Center of Start To Reset
TXRDY#
8
8
TRST Reset Pulse Width
40
40
N
Baud Rate Divisor
1
216-1
1
216-1
Bclk Baud Clock
16X of data rate
UNIT
ns
ns
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Bclk
ns
ns
Bclk
ns
Bclk
ns
ns
Bclk
ns
-
Hz
COMMENTS
* 55ns if VCC =
3.3V +10%/-5%
and
TA = 0 to 70oC
(See Figure 12)
26