XR19L400 Datasheet, PDF (16/45 Pages) Exar Corporation – SINGLE CHANNEL INTEGRATED UART AND RS-485 TRANSCEIVER
XR19L400
PRELIMINARY
SINGLE CHANNEL INTEGRATED UART AND RS-485 TRANSCEIVER
REV. P1.0.0
2.14.1.2 UART active, charge pump of RS-485 transceiver shut down
If the ACP pin is HIGH and the UART portion of the L400 is not in sleep mode, then the charge pump will
automatically shut down to conserve power if the following conditions are true:
■ no activity on the TX output signal
■ modem inputs have been idle for approximately 30 seconds
When these conditions are satisfied, the L400 shuts down the charge pump and tri-states the RS-485 drivers
to conserve power. In this mode, the RS-485 receivers are fully active and the internal registers of the L400
can be accessed. The time for the charge pump to resume normal operation after exiting the sleep mode is
typically 45µs. It will wake up by any of the following:
■ a receive data start bit transition on the RX input (LOW to HIGH)
■ a data byte is loaded to the transmitter, THR or FIFO
■ a LOW to HIGH transition on any of the modem or general purpose serial inputs
Because the receivers are fully active when the charge pump is turned off, any data received will be transferred
to/from the UART without any issues.
2.14.2 Full Sleep Mode
In full sleep mode, the L400 shuts down the charge pump and the internal oscillator. The L400 enters the full
sleep mode if the following conditions are satisfied:
■ the UART portion of the L400 is already in sleep mode (no output on XTAL2)
■ the ACP (Autosleep for Charge Pump) pin is HIGH
When these conditions are satisfied, both the UART and the charge pump will be in the sleep mode. In this
mode, the RS-485 receivers are fully active and the internal registers of the L400 can be accessed. The L400
exits the full sleep mode if either the ACP pin becomes LOW or the internal oscillator starts up. The time for the
charge pump to resume normal operation after exiting the full sleep mode is typically 45µs.
2.14.3 Power-Save Feature
This mode is in addition to the sleep mode and in this mode, the core logic of the L400 is isolated from the CPU
interface. If the address lines, data bus lines, IOW#, IOR# and CS# remain steady when the L400 is in full
sleep mode, the maximum current will be in the microamp range as specified in the DC Electrical
Characteristics on page 36. However, if the input lines are floating or are toggling while the L400 is in sleep
mode, the current can be up to 100 times more. If not using the Power-Save feature, an external buffer would
be required to keep the address and data bus lines from toggling or floating to achieve the low current. But if
the Power-Save feature is enabled (PwrSave pin connected to VCC), this will eliminate the need for an
external buffer by internally isolating the address, data and control signals from other bus activities that could
cause wasteful power drain (see Figure 1). The L400 enters Power-Save mode when this pin is connected to
VCC, and the UART portion of the L400 is already in sleep mode.
Since Power-Save mode isolates the address, data and control signals, the device will wake-up only by:
■ a receive data start bit transition, or
■ a change of logic state on any of the modem or general purpose serial inputs: i.e., any of the MSR bits 0-
3 shows a ’1’
The L400 will return to the Power-Save mode automatically after a read to the MSR (to reset the modem
inputs) and all interrupting conditions have been serviced and cleared. The L400 will stay in the Power-Save
mode of operation until it is disabled by setting IER bit-4 to a logic 0 and/or the Power-Save pin is connected to
GND.
If the L400 is awakened by any one of the above conditions, it issues an interrupt as soon as the oscillator
circuit is up and running and the device is ready to transmit/receive. This interrupt has the same encoding (bit-
0 of ISR register = 1) as "no interrupt pending" and will clear when the ISR register is read. This will show up in
the ISR register only if no other interrupts are enabled.
16