W77L32 Datasheet, PDF (12/76 Pages) Winbond – 8-BIT MICROCONTROLLER
W77L32/W77L032A/W77M032A
Data Pointer Select
Bit:
7
6
5
4
3
2
1
0
-
-
-
-
-
-
- DPS.0
Mnemonic: DPS
Address: 86h
DPS.0: This bit is used to select either the DPL,DPH pair or the DPL1, DPH1 pair as the active Data
Pointer. When set to 1, DPL1, DPH1 will be selected, otherwise DPL, DPH will be selected.
DPS.1 − 7: These bits are reserved, but will read 0.
Power Control
Bit:
7
6
5
SM0D SMOD0 -
4
3
2
1
0
-
GF1 GF0 PD IDL
Mnemonic: PCON
Address: 87h
SMOD : This bit doubles the serial port baud rate in mode 1, 2, and 3 when set to 1.
SMOD0: Framing Error Detection Enable: When SMOD0 is set to 1, then SCON.7(SCON1.7) indicates
a Frame Error and acts as the FE(FE_1) flag. When SMOD0 is 0, then SCON.7(SCON1.7)
acts as per the standard 8052 function.
GF1 − 0: These two bits are general purpose user flags.
PD:
Setting this bit causes the W77L032 to go into the POWER DOWN mode. In this mode all
the clocks are stopped and program execution is frozen.
IDL: Setting this bit causes the W77L032 to go into the IDLE mode. In this mode the clocks to the
CPU are stopped, so program execution is frozen. But the clock to the serial, timer and
interrupt blocks is not stopped, and these blocks continue operating.
Timer Control
Bit:
7
6
5
4
3
TF1 TR1 TF0 TR0 IE1
Mnemonic: TCON
2
1
0
IT
IE0
IT
Address: 88h
TF1:
TR1:
TF0:
TR0:
IE1:
IT1:
Timer 1 overflow flag: This bit is set when Timer 1 overflows. It is cleared automatically when
the program does a timer 1 interrupt service routine. Software can also set or clear this bit.
Timer 1 run control: This bit is set or cleared by software to turn timer/counter on or off.
Timer 0 overflow flag: This bit is set when Timer 0 overflows. It is cleared automatically when
the program does a timer 0 interrupt service routine. Software can also set or clear this bit.
Timer 0 run control: This bit is set or cleared by software to turn timer/counter on or off.
Interrupt 1 edge detect: Set by hardware when an edge/level is detected on INT1. This bit is
cleared by hardware when the service routine is vectored to only if the interrupt was edge
triggered. Otherwise it follows the pin.
Interrupt 1 type control: Set/cleared by software to specify falling edge/ low level triggered
external inputs.
- 12 -