N78E366A Data Sheet
Bit
Name
Description
1
-
Reserved.
0
BOS Brown-out status.
This bit indicates the VDD voltage level comparing with VBOD while Brown-out cir-
cuit is enabled. It is helpful to tell a Brown-out event or power resuming event oc-
currence. This bit is read-only and keeps 0 if Brown-out detection is not enabled.
0 = VDD voltage level is higher than VBOD.
1 = VDD voltage level is lower than VBOD.
[1] BODEN and BORST will be directly loaded from CONFIG2 bit 7 and bit 4 after all resets.
Table 21–1. BOF Reset Value
Reset source
Brown-out reset
Other resets
CBODEN (CONFIG2.7)
1
1
1
1
0
CBORST (CONFIG2.4)
1
1
0
0
X
VDD stable level
> VBOD always
> VBOD always
> VBOD
< VBOD
X
BOF
1
1
1
0
0
Note that if BOF is 1 after chip reset, it is strongly recommended to initialize the user’s program by
clearing BOF.
PCON – Power Control
7
6
SMOD
-
r/w
-
Address: 87H
5
4
3
2
1
0
-
POF
GF1
GF0
PD
IDL
-
r/w
r/w
r/w
r/w
r/w
reset value: see Table 6–2. N78E366A SFR Descriptions and Reset Values
Bit
Name
Description
4
POF Power-on reset flag.
This bit will be set as 1 after a power-on reset. It indicates a cold reset, a power-
on reset complete. This bit remains its value after any other resets. This flag is
recommended to be cleared via software.
- 106 -
Publication Release Date: March 11, 2011
Revision: V2.0