SI5600 Datasheet, PDF (7/28 Pages) List of Unclassifed Manufacturers – SiPHY-TM OC-192/STM-64 SONET/SDH TRANSCEIVER | |||
|
◁ |
Si5600
Table 3. AC Characteristics (RXDIN, RXDOUT, RXCLK1, RXCLK2)
(VDD = 1.8 V ±5%, TA = â40°C to 85°C)
Parameter
Symbol
Test Condition
Min Typ Max Unit
Output Clock Frequency
(RXCLK1)
Duty Cycle (RXCLK1, RXCLK2)
fclkout
tch/tcp, Figure 2
â
622
667 MHz
45
â
55
%
Output Rise and Fall Times
tR,tF
(RXCLK1, RXCLK2,RXDOUT)
Figure 3
â
50
â
ps
Data Invalid Prior to RXCLK1
tcq1
Figure 2
â
â
200
ps
Data Invalid After RXCLK1
tcq2
Figure 2
â
â
200
ps
Input Return Loss (RXIN)
400 kHzâ10.0 GHz
10.0 GHzâ16.0 GHz
18.7
â
TBD
â
â
dB
â
dB
Slicing Adjust Dynamic Range
Slicing Level Offset1
(referred to RXDIN)
Slicing Level Accuracy
Sampling Phase Adjustment2
LOS Threshold Dynamic Range
LOS Threshold Offset3
(referred to RXDIN)
LOS Threshold Accuracy
SLICELVL = 200â800 mV â20
â
SLICELVL = 200â800 mV â500
â
VSLICE
â5
â
PHASEADJ = 200â800 mV â45°
â
LOSLVL = 200â800 mV
10
â
LOSLVL = 200â800 mV â500
â
VLOS
â5
â
20
mV
500
µV
5
%
45o
50
mV
pk-pk
500
µV
5
%
Note:
1. Slice level (referred to RXDIN) is calculated as follows: VSLICE = (SLICE_LVL â 0.4 " VREF)/15.
2. Sample Phase Offset is calculated as follows: PHASE OFFSET = 45° (PHASEADJ â 0.4 " VREF)/0.3
3. LOS Threshold voltage (referred to RXDIN) is calculated as follows: VLOS = 30 mV + (LOS_LVL â 0.4 " VREF)/15.
Preliminary Rev. 0.31
7
|
▷ |