English
Language : 

SI5600 Datasheet, PDF (7/28 Pages) List of Unclassifed Manufacturers – SiPHY-TM OC-192/STM-64 SONET/SDH TRANSCEIVER
Si5600
Table 3. AC Characteristics (RXDIN, RXDOUT, RXCLK1, RXCLK2)
(VDD = 1.8 V ±5%, TA = –40°C to 85°C)
Parameter
Symbol
Test Condition
Min Typ Max Unit
Output Clock Frequency
(RXCLK1)
Duty Cycle (RXCLK1, RXCLK2)
fclkout
tch/tcp, Figure 2
—
622
667 MHz
45
—
55
%
Output Rise and Fall Times
tR,tF
(RXCLK1, RXCLK2,RXDOUT)
Figure 3
—
50
—
ps
Data Invalid Prior to RXCLK1
tcq1
Figure 2
—
—
200
ps
Data Invalid After RXCLK1
tcq2
Figure 2
—
—
200
ps
Input Return Loss (RXIN)
400 kHz–10.0 GHz
10.0 GHz–16.0 GHz
18.7
—
TBD
—
—
dB
—
dB
Slicing Adjust Dynamic Range
Slicing Level Offset1
(referred to RXDIN)
Slicing Level Accuracy
Sampling Phase Adjustment2
LOS Threshold Dynamic Range
LOS Threshold Offset3
(referred to RXDIN)
LOS Threshold Accuracy
SLICELVL = 200–800 mV –20
—
SLICELVL = 200–800 mV –500
—
VSLICE
–5
—
PHASEADJ = 200–800 mV –45°
—
LOSLVL = 200–800 mV
10
—
LOSLVL = 200–800 mV –500
—
VLOS
–5
—
20
mV
500
µV
5
%
45o
50
mV
pk-pk
500
µV
5
%
Note:
1. Slice level (referred to RXDIN) is calculated as follows: VSLICE = (SLICE_LVL – 0.4 " VREF)/15.
2. Sample Phase Offset is calculated as follows: PHASE OFFSET = 45° (PHASEADJ – 0.4 " VREF)/0.3
3. LOS Threshold voltage (referred to RXDIN) is calculated as follows: VLOS = 30 mV + (LOS_LVL – 0.4 " VREF)/15.
Preliminary Rev. 0.31
7