English
Language : 

CM312 Datasheet, PDF (46/56 Pages) List of Unclassifed Manufacturers – Communications utilityModule
NE2000 0x60 0x5 0x340
If the use of ODI drivers is requested or preferred, it is possible to use the ODI packet driver:
LSL
NE2000
IPXODI
ODIPKT 1 0x60
NET.CFG
LINK SUPPORT
buffers 8 850
LINK DRIVER NE2000
PORT 360
INT 5
FRAME ETHERNET_802.3
FRAME ETHERNET_II
FRAME ETHERNET_802.2
FRAME ETHERNET_SNAP
PROTOCOL IPX 0 ETHERNET_802.3
Remote Boot Examples
The following examples illustrate configuration of the module for use in a remote boot application.
RPL from a WindowsNT server 3.5
1. Install RPL Service on your WindowsNT Server
2. Copy DOS 6.22 files in WINNT35\RPL\RPLFILES\BINFILES\DOS622
3. Copy NE2000.DOS in WINNT35\RPL\BBLOCKS\NDIS;
remember not to flag the files IO.SYS and MSDOS.SYS as Hidden or System.
4. From a DOS window run RPLCMD
5. add Vendor:
VendorName=00E0C7
comment=RTDUSA NE2000
6. add boot (b - a):
BootName= DOS
VendorName=00D081
BBCFile=BBLOCK\NETBEUI\NE2000\DOSBB.CNF
7. Restart WindowsNT and start RPL Service.
Now the cpuModule used with the utilityModule can remotely boot DOS from WindowsNT Server
DOSBB.CNF
; DOS on NE2000 Ethernet
BASE D0H
RPL BBLOCK\RPLBOOT.SYS
LDR BBLOCK\RPLSTART.COM ~
DAT BBLOCK\NETBEUI\NE2000\PROTOCOL.INI
DRV BBLOCK\RPLDISK.SYS ~ ~ ~
EXE BBLOCK\RPLPRO1.COM ~ 2 ~
CM312 Quad Serial utilityModule
36
RTD Embedded Technologies, Inc.